Delta SIG80-110MHLED Exhaust Fan Specifications

ENERGY STAR PD #2343183 · Bathroom/Utility Room · Qualified 2018-01-19
Verified Specification Summary

In EPA dataset 8dv7-nngq, Delta SIG80-110MHLED tests at 110 CFM free discharge (112.9 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 12.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 112 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110MHLED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 112.9 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
12.8 CFM/W (#60/1,145)
Static Retention
102.6% @ 0.25"
Motor Draw
8.6 W (3.1 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SIG80-110MHLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SIG80-110MHLED (EPA filing PD #2343183) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.9 CFM out of 110 CFM (102.6% retention, 14.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places SIG80-110MHLED (series: BreezSignature) (PD #2343183) among 121 Delta entries qualified through 2018-01-19. Lighting kit: Yes. At 12.8 CFM/W (#60 of 1,145, top 5.5% of 1,145 rated models, more efficient than 94.5% of rated models, 8.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.6 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 75.3 kWh/yr (~$12.05/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

Why avoid unvented attic termination with Delta SIG80-110MHLED?

Under ASHRAE 62.2 best practice, Delta SIG80-110MHLED needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Delta SIG80-110MHLED?

Before cutting ceiling drywall or sizing attic transitions for Delta SIG80-110MHLED, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SIG80-110MHLED / BreezSignature PD ID 2343183 (Qualified 2018-01-19)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Delta SIG80-110MHLED?

Bathroom ventilation sizing below maps Delta SIG80-110MHLED motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Delta SIG80-110MHLED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.9 CFM
Tall Bath (9-ft Ceiling)Up to 100 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.1 kWh/yr (~$0.50/yr)8.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.275.3 kWh/yr (~$12.05/yr)8.6 W x 8,760 hrs / 1,000

What peer models sit nearest Delta SIG80-110MHLED in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta SIG80-110MHLED.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter

What percentage of room demand does Delta SIG80-110MHLED cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta SIG80-110MHLED tested delivery.

Does Delta SIG80-110MHLED suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta SIG80-110MHLED for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 112.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 112 sq ft
  • Best application: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Delta SIG80-110MHLED?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta SIG80-110MHLED.

What acoustic sone tier does Delta SIG80-110MHLED occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Delta SIG80-110MHLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Delta SIG80-110MHLED add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Delta SIG80-110MHLED averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Delta SIG80-110MHLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110MHLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SIG80-110MHLED?

Delta SIG80-110MHLED features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SIG80-110MHLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110MHLED's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Delta SIG80-110MHLED pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110MHLED easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Delta SIG80-110MHLED in a bathroom remodel?

Avoid specifying Delta SIG80-110MHLED in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Delta SIG80-110MHLED airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta SIG80-110MHLED achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories