Skip to main content
Grant Estimator

Delta SLM50-110LED-C Exhaust Fan Specifications

ENERGY STAR PD #2394317 · Bathroom/Utility Room · Qualified 2022-02-18
Verified Specification Summary

Tested under HVI protocols, the Delta SLM50-110LED-C exhaust unit achieves 110 CFM at 0.1 in. w.g. (108.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 7.1 CFM/W efficacy, covering standard baths up to 108 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM50-110LED-C Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 108.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.1 CFM/W (#415/1,145)
Static Retention
98.6% @ 0.25"
Motor Draw
15.5 W (5.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SLM50-110LED-C vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SLM50-110LED-C (EPA filing PD #2394317) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108.5 CFM out of 110 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta SLM50-110LED-C (series: BreezSlim) under PD #2394317 (121 models registered, 2022-02-18). Lighting kit: Yes. At 7.1 CFM/W (#415 of 1,145, top 36.6% of 1,145 rated models, more efficient than 63.4% of rated models, 2.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.5 watts, about 5.7 kWh/yr (~$0.91/yr at $0.16/kWh) for 1 hr/day shower timers or 135.8 kWh/yr (~$21.73/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7131-04 (100.0 CFM).

What attic duct routing preserves Delta SLM50-110LED-C CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta SLM50-110LED-C, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Delta SLM50-110LED-C measure up on airflow and noise ratings?

Each row below breaks down Delta SLM50-110LED-C certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SLM50-110LED-C / BreezSlim PD ID 2394317 (Qualified 2022-02-18)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (108.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Delta SLM50-110LED-C CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta SLM50-110LED-C
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 108 sq ft1 CFM/sq ft @ 108.5 CFM
Tall Bath (9-ft Ceiling)Up to 96 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 58 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.7 kWh/yr (~$0.91/yr)15.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2135.8 kWh/yr (~$21.73/yr)15.5 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Delta SLM50-110LED-C?

Compare Delta SLM50-110LED-C side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech 7131-04 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter
Utilitech 7115-01 100 / 95.4 CFM 1.5 sones 6.5 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Can you size Delta SLM50-110LED-C for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta SLM50-110LED-C verified capacity.

What plumbing or duct constraints rule out Delta SLM50-110LED-C?

Compare where Delta SLM50-110LED-C excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 108.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around ENERGY STAR sones up to 108 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Delta SLM50-110LED-C?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta SLM50-110LED-C.

Is Delta SLM50-110LED-C energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta SLM50-110LED-C pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM50-110LED-C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SLM50-110LED-C?

Delta SLM50-110LED-C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SLM50-110LED-C's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM50-110LED-C's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta SLM50-110LED-C serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta SLM50-110LED-C supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Delta SLM50-110LED-C for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta SLM50-110LED-C lacks adequate reserve.

How does Delta SLM50-110LED-C handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta SLM50-110LED-C yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Delta SLM50-110LED-C quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Delta SLM50-110LED-C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories