Skip to main content
Grant Estimator

Delta SLM80-110D-C Exhaust Fan Specifications

ENERGY STAR PD #2374794 · Bathroom/Utility Room · Qualified 2021-03-12
Verified Specification Summary

Certified by EPA ENERGY STAR, Delta SLM80-110D-C delivers 110 CFM free-air (114 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 114 sq ft (8-ft height) or 101 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM80-110D-C Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 114 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.0 CFM/W (#352/1,145)
Static Retention
103.6% @ 0.25"
Motor Draw
13.8 W (5.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SLM80-110D-C vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SLM80-110D-C (EPA filing PD #2374794) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114 CFM out of 110 CFM (103.6% retention, 15.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta SLM80-110D-C (series: BreezSlim) under PD #2374794 (121 models registered, 2021-03-12). Lighting kit: No. At 8.0 CFM/W (#352 of 1,145, top 31.0% of 1,145 rated models, more efficient than 69.0% of rated models, 3.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.8 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 120.9 kWh/yr (~$19.34/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech 7115-02 (100.0 CFM).

Why does rigid 4 in. diameter ducting protect Delta SLM80-110D-C airflow?

Connecting Delta SLM80-110D-C through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Delta SLM80-110D-C performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM80-110D-C lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SLM80-110D-C / BreezSlim PD ID 2374794 (Qualified 2021-03-12)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (114 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Delta SLM80-110D-C?

Calculated coverage metrics translate Delta SLM80-110D-C airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta SLM80-110D-C
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 114 sq ft1 CFM/sq ft @ 114 CFM
Tall Bath (9-ft Ceiling)Up to 101 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 64 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.0 kWh/yr (~$0.80/yr)13.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2120.9 kWh/yr (~$19.34/yr)13.8 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Delta SLM80-110D-C?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-MB 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Delta SLM80-110D-C match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM80-110D-C percentage capacity without sending data.

Which bath layouts should avoid specifying Delta SLM80-110D-C?

Match Delta SLM80-110D-C directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 64 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 114 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Delta SLM80-110D-C?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM80-110D-C.

What does Delta SLM80-110D-C cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Delta SLM80-110D-C 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Delta SLM80-110D-C pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM80-110D-C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SLM80-110D-C?

Delta SLM80-110D-C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SLM80-110D-C's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM80-110D-C's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Delta SLM80-110D-C ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta SLM80-110D-C covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Delta SLM80-110D-C run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta SLM80-110D-C.

What happens to Delta SLM80-110D-C CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Delta SLM80-110D-C moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Delta SLM80-110D-C sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Delta SLM80-110D-C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)