Skip to main content
Grant Estimator

Delta SLM80-110DLED Exhaust Fan Specifications

ENERGY STAR PD #2367520 · Bathroom/Utility Room · Qualified 2020-10-16
Verified Specification Summary

Certified by EPA ENERGY STAR, Delta SLM80-110DLED delivers 110 CFM free-air (108.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 7.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 108 sq ft (8-ft height) or 96 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM80-110DLED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 108.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.1 CFM/W (#415/1,145)
Static Retention
98.6% @ 0.25"
Motor Draw
15.5 W (5.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SLM80-110DLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SLM80-110DLED (EPA filing PD #2367520) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108.5 CFM out of 110 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2367520 verifies SLM80-110DLED (series: BreezSlim) under Delta (121 listed models, qualified 2020-10-16). Lighting kit: Yes. At 7.1 CFM/W (#415 of 1,145, top 36.6% of 1,145 rated models, more efficient than 63.4% of rated models, 2.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.5 watts, about 5.7 kWh/yr (~$0.91/yr at $0.16/kWh) for 1 hr/day shower timers or 135.8 kWh/yr (~$21.73/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7131-04 (100.0 CFM).

Why does rigid 4 in. diameter ducting protect Delta SLM80-110DLED airflow?

Connecting Delta SLM80-110DLED through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Delta SLM80-110DLED performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM80-110DLED lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SLM80-110DLED / BreezSlim PD ID 2367520 (Qualified 2020-10-16)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (108.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Delta SLM80-110DLED?

Calculated coverage metrics translate Delta SLM80-110DLED airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta SLM80-110DLED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 108 sq ft1 CFM/sq ft @ 108.5 CFM
Tall Bath (9-ft Ceiling)Up to 96 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 58 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.7 kWh/yr (~$0.91/yr)15.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2135.8 kWh/yr (~$21.73/yr)15.5 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Delta SLM80-110DLED?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech 7131-04 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter
Utilitech 7115-01 100 / 95.4 CFM 1.5 sones 6.5 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Delta SLM80-110DLED match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM80-110DLED percentage capacity without sending data.

Who should not install Delta SLM80-110DLED in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta SLM80-110DLED for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 58 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 108.5 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Delta SLM80-110DLED?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM80-110DLED.

Does Delta SLM80-110DLED satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta SLM80-110DLED clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Delta SLM80-110DLED undersized or poorly matched for a bath renovation?

Skip Delta SLM80-110DLED if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Delta SLM80-110DLED CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta SLM80-110DLED registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Delta SLM80-110DLED sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Delta SLM80-110DLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Delta SLM80-110DLED?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Delta SLM80-110DLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM80-110DLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SLM80-110DLED?

Delta SLM80-110DLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SLM80-110DLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM80-110DLED's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories