Certified by EPA ENERGY STAR, Delta SLM80-110DLED delivers 110 CFM free-air (108.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 7.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 108 sq ft (8-ft height) or 96 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM80-110DLED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 108.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.1 CFM/W (#415/1,145)
- Static Retention
- 98.6% @ 0.25"
- Motor Draw
- 15.5 W (5.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta SLM80-110DLED vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SLM80-110DLED (EPA filing PD #2367520) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108.5 CFM out of 110 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2367520 verifies SLM80-110DLED (series: BreezSlim) under Delta (121 listed models, qualified 2020-10-16). Lighting kit: Yes. At 7.1 CFM/W (#415 of 1,145, top 36.6% of 1,145 rated models, more efficient than 63.4% of rated models, 2.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.5 watts, about 5.7 kWh/yr (~$0.91/yr at $0.16/kWh) for 1 hr/day shower timers or 135.8 kWh/yr (~$21.73/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7131-04 (100.0 CFM).
Why does rigid 4 in. diameter ducting protect Delta SLM80-110DLED airflow?
Connecting Delta SLM80-110DLED through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Delta SLM80-110DLED performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM80-110DLED lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SLM80-110DLED / BreezSlim | PD ID 2367520 (Qualified 2020-10-16) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (108.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Delta SLM80-110DLED?
Calculated coverage metrics translate Delta SLM80-110DLED airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 108 sq ft | 1 CFM/sq ft @ 108.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 58 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.7 kWh/yr (~$0.91/yr) | 15.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 135.8 kWh/yr (~$21.73/yr) | 15.5 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Delta SLM80-110DLED?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Utilitech 7131-04 | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
| Utilitech 7115-01 | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Does Delta SLM80-110DLED match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM80-110DLED percentage capacity without sending data.
Who should not install Delta SLM80-110DLED in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta SLM80-110DLED for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 58 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 108.5 CFM net static output
- Primary match: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Delta SLM80-110DLED?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM80-110DLED.
Does Delta SLM80-110DLED satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta SLM80-110DLED clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Delta SLM80-110DLED undersized or poorly matched for a bath renovation?
Skip Delta SLM80-110DLED if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Delta SLM80-110DLED CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta SLM80-110DLED registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Delta SLM80-110DLED sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Delta SLM80-110DLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Delta SLM80-110DLED?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Delta SLM80-110DLED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM80-110DLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SLM80-110DLED?
Delta SLM80-110DLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SLM80-110DLED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM80-110DLED's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)