Tested under HVI protocols, the Delta SLM80-110H-C exhaust unit achieves 110 CFM at 0.1 in. w.g. (114 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 8.0 CFM/W efficacy, covering standard baths up to 114 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM80-110H-C Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 114 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.0 CFM/W (#352/1,145)
- Static Retention
- 103.6% @ 0.25"
- Motor Draw
- 13.8 W (5.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta SLM80-110H-C vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SLM80-110H-C (EPA filing PD #2394304) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114 CFM out of 110 CFM (103.6% retention, 15.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Delta SLM80-110H-C (series: BreezSlim) under PD #2394304 (121 models registered, 2022-02-18). Lighting kit: No. At 8.0 CFM/W (#352 of 1,145, top 31.0% of 1,145 rated models, more efficient than 69.0% of rated models, 3.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.8 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 120.9 kWh/yr (~$19.34/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech 7115-02 (100.0 CFM).
What attic duct routing preserves Delta SLM80-110H-C CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta SLM80-110H-C, preventing premature peeling paint and mold growth.
How does Delta SLM80-110H-C measure up on airflow and noise ratings?
Each row below breaks down Delta SLM80-110H-C certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SLM80-110H-C / BreezSlim | PD ID 2394304 (Qualified 2022-02-18) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (114 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Delta SLM80-110H-C CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.0 kWh/yr (~$0.80/yr) | 13.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 120.9 kWh/yr (~$19.34/yr) | 13.8 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Delta SLM80-110H-C?
Compare Delta SLM80-110H-C side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-MB | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Can you size Delta SLM80-110H-C for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta SLM80-110H-C verified capacity.
Where should contractors skip Delta SLM80-110H-C on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta SLM80-110H-C carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 114 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 114 sq ft
- Works well for: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Delta SLM80-110H-C?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta SLM80-110H-C.
How much power does Delta SLM80-110H-C consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Delta SLM80-110H-C draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Delta SLM80-110H-C pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM80-110H-C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SLM80-110H-C?
Delta SLM80-110H-C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SLM80-110H-C's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM80-110H-C's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Delta SLM80-110H-C score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta SLM80-110H-C delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Delta SLM80-110H-C?
Rule out Delta SLM80-110H-C when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Delta SLM80-110H-C capacity?
Because static drag at 0.25 in. w.g. lowers Delta SLM80-110H-C from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Delta SLM80-110H-C compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Delta SLM80-110H-C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)