Delta SIG80-110DLED Exhaust Fan Specifications

ENERGY STAR PD #2343186 · Bathroom/Utility Room · Qualified 2018-01-19
Verified Specification Summary

Homeowners specifying Delta SIG80-110DLED gain 110 CFM at 0.1 in. w.g. (108 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, venting bathrooms up to 108 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110DLED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 108 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.3 CFM/W (#258/1,145)
Static Retention
98.2% @ 0.25"
Motor Draw
11.8 W (4.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SIG80-110DLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SIG80-110DLED (EPA filing PD #2343186) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108 CFM out of 110 CFM (98.2% retention, 10.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta SIG80-110DLED (series: BreezSignature) under PD #2343186 (121 models registered, 2018-01-19). Lighting kit: Yes. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.8 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 103.4 kWh/yr (~$16.54/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

Which exterior damper path suits Delta SIG80-110DLED best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Delta SIG80-110DLED housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Delta SIG80-110DLED acoustic and static metrics stand?

Compare Delta SIG80-110DLED published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SIG80-110DLED / BreezSignature PD ID 2343186 (Qualified 2018-01-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (108 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Delta SIG80-110DLED handle taller ceilings or walk-in tub steam?

Evaluate how Delta SIG80-110DLED scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Delta SIG80-110DLED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 108 sq ft1 CFM/sq ft @ 108 CFM
Tall Bath (9-ft Ceiling)Up to 96 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 58 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.3 kWh/yr (~$0.69/yr)11.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2103.4 kWh/yr (~$16.54/yr)11.8 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Delta SIG80-110DLED?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Is Delta SIG80-110DLED sized right for your shower or tub room?

Check whether Delta SIG80-110DLED clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

When does Delta SIG80-110DLED fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta SIG80-110DLED.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 58 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 108 CFM net static output
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Delta SIG80-110DLED?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Delta SIG80-110DLED.

Which bathroom layouts should pick a larger blower than Delta SIG80-110DLED?

Do not force Delta SIG80-110DLED into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Delta SIG80-110DLED retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Delta SIG80-110DLED produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Delta SIG80-110DLED disturb adjacent bedrooms during night use?

Acoustic measurement places Delta SIG80-110DLED at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Delta SIG80-110DLED continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Delta SIG80-110DLED draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Delta SIG80-110DLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110DLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SIG80-110DLED?

Delta SIG80-110DLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SIG80-110DLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110DLED's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Delta SIG80-110DLED code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110DLED clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories