Skip to main content
Grant Estimator

Delta ELT80-110MH Exhaust Fan Specifications

ENERGY STAR PD #2343271 · Bathroom/Utility Room · Qualified 2018-12-21
Verified Specification Summary

Homeowners specifying Delta ELT80-110MH gain 110 CFM at 0.1 in. w.g. (96.9 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 11.5 CFM/W efficacy, venting bathrooms up to 96 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110MH Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 96.9 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.5 CFM/W (#106/1,145)
Static Retention
88.1% @ 0.25"
Motor Draw
9.6 W (3.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta ELT80-110MH vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110MH (EPA filing PD #2343271) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 96.9 CFM out of 110 CFM (88.1% retention, 0.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Delta maintains 121 active ENERGY STAR blowers; ELT80-110MH (series: BreezElite) (PD #2343271) gained qualification on 2018-12-21. Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.6 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 84.1 kWh/yr (~$13.46/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Revent RVL110 (110.0 CFM).

Which exterior damper path suits Delta ELT80-110MH best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Delta ELT80-110MH housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Delta ELT80-110MH acoustic and static metrics stand?

Compare Delta ELT80-110MH published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series ELT80-110MH / BreezElite PD ID 2343271 (Qualified 2018-12-21)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (96.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Delta ELT80-110MH handle taller ceilings or walk-in tub steam?

Evaluate how Delta ELT80-110MH scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110MH
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 96 sq ft1 CFM/sq ft @ 96.9 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 46 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.5 kWh/yr (~$0.56/yr)9.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.284.1 kWh/yr (~$13.46/yr)9.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Delta ELT80-110MH?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter

Is Delta ELT80-110MH sized right for your shower or tub room?

Check whether Delta ELT80-110MH clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Delta ELT80-110MH?

Compare where Delta ELT80-110MH excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 46 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 96.9 CFM net static output
  • Suited to: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Delta ELT80-110MH?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Delta ELT80-110MH.

How does Delta ELT80-110MH handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ELT80-110MH yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Delta ELT80-110MH quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Delta ELT80-110MH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Delta ELT80-110MH energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta ELT80-110MH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110MH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta ELT80-110MH?

Delta ELT80-110MH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta ELT80-110MH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110MH's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta ELT80-110MH serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta ELT80-110MH supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Delta ELT80-110MH for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ELT80-110MH lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories