Certified by EPA ENERGY STAR, Delta SLM70 delivers 70 CFM free-air (58.7 CFM at 0.25 in. w.g.) and registers #520 of 607 in quietness (1.9 sones) and delivers 5.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 58 sq ft (8-ft height) or 52 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM70 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 58.7 CFM
- Noise @ 0.1"
- 1.9 sones (#520/607)
- Efficacy Rank
- 5.8 CFM/W (#461/1,145)
- Static Retention
- 83.9% @ 0.25"
- Motor Draw
- 12.1 W (4.4 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Delta SLM70 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.9 sones (#520 of 607 rated models, 0.90 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.7 CFM at 0.25 in. w.g. (83.9% retention, 3.8 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Delta maintains 121 active ENERGY STAR blowers; SLM70 (series: BreezSlim) (PD #2250877) gained qualification on 2015-10-01. Lighting kit: No. At 5.8 CFM/W (#461 of 1,145, top 40.7% of 1,145 rated models, more efficient than 59.3% of rated models, 1.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.1 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 106.0 kWh/yr (~$16.96/yr) continuously. Closest competing matches include Utilitech 7111-04-L (70.0 CFM) and Revent RVL70 (70.0 CFM).
How noisy is Delta SLM70 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Delta SLM70 measures 1.9 sones across the 1,145-model registry.
Why does rigid 3 in. diameter ducting protect Delta SLM70 airflow?
Connecting Delta SLM70 through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Delta SLM70 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM70 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SLM70 / BreezSlim | PD ID 2250877 (Qualified 2015-10-01) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (58.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Delta SLM70?
Calculated coverage metrics translate Delta SLM70 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 58 sq ft | 1 CFM/sq ft @ 58.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.4 kWh/yr (~$0.70/yr) | 12.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.0 kWh/yr (~$16.96/yr) | 12.1 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Delta SLM70?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7111-04-L | 70 / 56.5 CFM | 2.0 sones (+0.10) | 7.0 CFM/W | 3 in. diameter |
| Revent RVL70 | 70 / 72.3 CFM | 2.0 sones (+0.10) | 7.7 CFM/W | 4 in. diameter |
| Revent RVLH70 | 70 / 72.3 CFM | 2.0 sones (+0.10) | 7.7 CFM/W | 4 in. diameter |
| Broan BEL7A | 70 / 57.4 CFM | 2.0 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 299650A | 70 / 58.9 CFM | 2.0 sones (+0.10) | 3.8 CFM/W | 3 in. diameter |
Does Delta SLM70 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM70 percentage capacity without sending data.
When does Delta SLM70 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta SLM70.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 58.7 CFM net static output
- Target scenario: Collar pairs with 3 in. diameter duct straight outdoors
Which homeowner questions come up most for Delta SLM70?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM70.
Is Delta SLM70 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta SLM70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Delta SLM70?
Do not force Delta SLM70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Delta SLM70 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Delta SLM70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.
Will Delta SLM70 disturb adjacent bedrooms during night use?
Acoustic measurement places Delta SLM70 at 1.9 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Delta SLM70 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Delta SLM70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Delta SLM70 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SLM70?
Delta SLM70 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SLM70's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM70's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)