The Delta SMT150D (BreezSmart) moves 150 CFM at 0.1 in. w.g. (150.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 8.9 CFM/W efficacy, sizing bathrooms up to 150 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SMT150D Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 150.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.9 CFM/W (#300/1,145)
- Static Retention
- 100.3% @ 0.25"
- Motor Draw
- 16.9 W (6.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Delta SMT150D vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SMT150D (EPA filing PD #2287985) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 150.5 CFM out of 150 CFM (100.3% retention, 12.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #2287985 verifies SMT150D (series: BreezSmart) under Delta (121 listed models, qualified 2017-01-06). Lighting kit: No. At 8.9 CFM/W (#300 of 1,145, top 26.6% of 1,145 rated models, more efficient than 73.4% of rated models, 4.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.9 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.0 kWh/yr (~$23.68/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 300 (167.0 CFM).
How does duct geometry alter Delta SMT150D static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Delta SMT150D?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta SMT150D alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SMT150D / BreezSmart | PD ID 2287985 (Qualified 2017-01-06) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (150.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Delta SMT150D ventilate safely?
Sizing outputs below convert Delta SMT150D tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 16.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 148.0 kWh/yr (~$23.68/yr) | 16.9 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Delta SMT150D closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 300 | 167 / N/A CFM | 1.9 sones | 9.9 CFM/W | 8 x 6 in. rectangular |
| Utilitech 7116-02 | 150 / 123.8 CFM | 1.0 sones | 8.1 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
Will Delta SMT150D clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Delta SMT150D satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
What plumbing or duct constraints rule out Delta SMT150D?
Compare where Delta SMT150D excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 100 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 150 sq ft with 8-ft ceilings (133 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Delta SMT150D?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta SMT150D.
Is Delta SMT150D quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Delta SMT150D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Delta SMT150D energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta SMT150D pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SMT150D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SMT150D?
Delta SMT150D features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SMT150D's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SMT150D's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Delta SMT150D serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta SMT150D supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Delta SMT150D for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta SMT150D lacks adequate reserve.
How does Delta SMT150D handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta SMT150D yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)