In EPA dataset 8dv7-nngq, DewStop - Breeze Easy F300-5080110-W1 tests at 110 CFM free discharge (117 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 117 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside DewStop - Breeze Easy F300-5080110-W1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 117 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 11.8 CFM/W (#90/1,145)
- Static Retention
- 106.4% @ 0.25"
- Motor Draw
- 9.3 W (3.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does DewStop - Breeze Easy F300-5080110-W1 vs. 1,145-Model ENERGY STAR Benchmarks show?
DewStop - Breeze Easy F300-5080110-W1 (EPA filing PD #4510678) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 117 CFM out of 110 CFM (106.4% retention, 18.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside DewStop - Breeze Easy's 8-unit lineup, F300-5080110-W1 (series: Breeze Easy) carries PD #4510678 dating to 2025-09-05. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.3 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 81.5 kWh/yr (~$13.04/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).
Why avoid unvented attic termination with DewStop - Breeze Easy F300-5080110-W1?
Under ASHRAE 62.2 best practice, DewStop - Breeze Easy F300-5080110-W1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern DewStop - Breeze Easy F300-5080110-W1?
Before cutting ceiling drywall or sizing attic transitions for DewStop - Breeze Easy F300-5080110-W1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | DewStop - Breeze Easy (8 models) | ENERGY STAR Certified Partner |
| Model Number & Series | F300-5080110-W1 / Breeze Easy | PD ID 4510678 (Qualified 2025-09-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (117 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit DewStop - Breeze Easy F300-5080110-W1?
Bathroom ventilation sizing below maps DewStop - Breeze Easy F300-5080110-W1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 117 sq ft | 1 CFM/sq ft @ 117 CFM |
| Tall Bath (9-ft Ceiling) | Up to 104 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 67 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.4 kWh/yr (~$0.54/yr) | 9.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 81.5 kWh/yr (~$13.04/yr) | 9.3 W x 8,760 hrs / 1,000 |
What peer models sit nearest DewStop - Breeze Easy F300-5080110-W1 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to DewStop - Breeze Easy F300-5080110-W1.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
What percentage of room demand does DewStop - Breeze Easy F300-5080110-W1 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against DewStop - Breeze Easy F300-5080110-W1 tested delivery.
When does DewStop - Breeze Easy F300-5080110-W1 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering DewStop - Breeze Easy F300-5080110-W1.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 117 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 117 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for DewStop - Breeze Easy F300-5080110-W1?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing DewStop - Breeze Easy F300-5080110-W1.
Is DewStop - Breeze Easy F300-5080110-W1 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), DewStop - Breeze Easy F300-5080110-W1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than DewStop - Breeze Easy F300-5080110-W1?
Do not force DewStop - Breeze Easy F300-5080110-W1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does DewStop - Breeze Easy F300-5080110-W1 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, DewStop - Breeze Easy F300-5080110-W1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will DewStop - Breeze Easy F300-5080110-W1 disturb adjacent bedrooms during night use?
Acoustic measurement places DewStop - Breeze Easy F300-5080110-W1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running DewStop - Breeze Easy F300-5080110-W1 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of DewStop - Breeze Easy F300-5080110-W1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can DewStop - Breeze Easy F300-5080110-W1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from DewStop - Breeze Easy F300-5080110-W1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing DewStop - Breeze Easy F300-5080110-W1?
DewStop - Breeze Easy F300-5080110-W1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change DewStop - Breeze Easy F300-5080110-W1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing DewStop - Breeze Easy F300-5080110-W1's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)