Skip to main content
Grant Estimator

DewStop - Breeze Easy F300-5080110-W1 Exhaust Fan Specifications

ENERGY STAR PD #4510678 · Bathroom/Utility Room · Qualified 2025-09-05
Verified Specification Summary

In EPA dataset 8dv7-nngq, DewStop - Breeze Easy F300-5080110-W1 tests at 110 CFM free discharge (117 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 117 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside DewStop - Breeze Easy F300-5080110-W1 Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
110 / 117 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.8 CFM/W (#90/1,145)
Static Retention
106.4% @ 0.25"
Motor Draw
9.3 W (3.4 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does DewStop - Breeze Easy F300-5080110-W1 vs. 1,145-Model ENERGY STAR Benchmarks show?

DewStop - Breeze Easy F300-5080110-W1 (EPA filing PD #4510678) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 117 CFM out of 110 CFM (106.4% retention, 18.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside DewStop - Breeze Easy's 8-unit lineup, F300-5080110-W1 (series: Breeze Easy) carries PD #4510678 dating to 2025-09-05. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.3 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 81.5 kWh/yr (~$13.04/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

Why avoid unvented attic termination with DewStop - Breeze Easy F300-5080110-W1?

Under ASHRAE 62.2 best practice, DewStop - Breeze Easy F300-5080110-W1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern DewStop - Breeze Easy F300-5080110-W1?

Before cutting ceiling drywall or sizing attic transitions for DewStop - Breeze Easy F300-5080110-W1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share DewStop - Breeze Easy (8 models) ENERGY STAR Certified Partner
Model Number & Series F300-5080110-W1 / Breeze Easy PD ID 4510678 (Qualified 2025-09-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (117 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit DewStop - Breeze Easy F300-5080110-W1?

Bathroom ventilation sizing below maps DewStop - Breeze Easy F300-5080110-W1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for DewStop - Breeze Easy F300-5080110-W1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 117 sq ft1 CFM/sq ft @ 117 CFM
Tall Bath (9-ft Ceiling)Up to 104 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 67 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.4 kWh/yr (~$0.54/yr)9.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.281.5 kWh/yr (~$13.04/yr)9.3 W x 8,760 hrs / 1,000

What peer models sit nearest DewStop - Breeze Easy F300-5080110-W1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to DewStop - Breeze Easy F300-5080110-W1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter

What percentage of room demand does DewStop - Breeze Easy F300-5080110-W1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against DewStop - Breeze Easy F300-5080110-W1 tested delivery.

When does DewStop - Breeze Easy F300-5080110-W1 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering DewStop - Breeze Easy F300-5080110-W1.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 117 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 117 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for DewStop - Breeze Easy F300-5080110-W1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing DewStop - Breeze Easy F300-5080110-W1.

Is DewStop - Breeze Easy F300-5080110-W1 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), DewStop - Breeze Easy F300-5080110-W1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than DewStop - Breeze Easy F300-5080110-W1?

Do not force DewStop - Breeze Easy F300-5080110-W1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does DewStop - Breeze Easy F300-5080110-W1 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, DewStop - Breeze Easy F300-5080110-W1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will DewStop - Breeze Easy F300-5080110-W1 disturb adjacent bedrooms during night use?

Acoustic measurement places DewStop - Breeze Easy F300-5080110-W1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running DewStop - Breeze Easy F300-5080110-W1 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of DewStop - Breeze Easy F300-5080110-W1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can DewStop - Breeze Easy F300-5080110-W1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from DewStop - Breeze Easy F300-5080110-W1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing DewStop - Breeze Easy F300-5080110-W1?

DewStop - Breeze Easy F300-5080110-W1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change DewStop - Breeze Easy F300-5080110-W1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing DewStop - Breeze Easy F300-5080110-W1's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories