The Fantech FG 4 (40402) (FG Series) moves 100 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 5.5 CFM/W efficacy, sizing bathrooms up to 100 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 4 (40402) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.5 CFM/W (#471/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 18.2 W (6.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Fantech FG 4 (40402) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech FG 4 (40402) (EPA filing PD #2394306) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Fantech's 52-unit lineup, FG 4 (40402) (series: FG Series) carries PD #2394306 dating to 2022-04-01. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Utilitech 7115-01 (100.0 CFM) and ACIQ AES100 (100.0 CFM).
How does duct geometry alter Fantech FG 4 (40402) static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Fantech FG 4 (40402)?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Fantech FG 4 (40402) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FG 4 (40402) / FG Series | PD ID 2394306 (Qualified 2022-04-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Fantech FG 4 (40402) ventilate safely?
Sizing outputs below convert Fantech FG 4 (40402) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Fantech FG 4 (40402) closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7115-01 | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| ACIQ AES100 | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| CFM TF100N | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| S&P PCLP100XP | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
Will Fantech FG 4 (40402) clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Fantech FG 4 (40402) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Fantech FG 4 (40402) in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech FG 4 (40402) for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 100 sq ft with 8-ft ceilings (88 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Fantech FG 4 (40402)?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Fantech FG 4 (40402).
How does Fantech FG 4 (40402) sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Fantech FG 4 (40402) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Fantech FG 4 (40402)?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Fantech FG 4 (40402) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 4 (40402)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech FG 4 (40402)?
Fantech FG 4 (40402) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech FG 4 (40402)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 4 (40402)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Fantech FG 4 (40402) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech FG 4 (40402) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Fantech FG 4 (40402) undersized or poorly matched for a bath renovation?
Skip Fantech FG 4 (40402) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Fantech FG 4 (40402) CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech FG 4 (40402) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)