Skip to main content
Grant Estimator

Greenheck SP-AP0511W-1 Exhaust Fan Specifications

ENERGY STAR PD #2406839 · Bathroom/Utility Room · Qualified 2023-01-13
Verified Specification Summary

Tested under HVI protocols, the Greenheck SP-AP0511W-1 exhaust unit achieves 110 CFM at 0.1 in. w.g. (126.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.8 CFM/W efficacy, covering standard baths up to 126 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-AP0511W-1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 126.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.8 CFM/W (#90/1,145)
Static Retention
114.6% @ 0.25"
Motor Draw
9.3 W (3.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-AP0511W-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-AP0511W-1 (EPA filing PD #2406839) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 126.1 CFM out of 110 CFM (114.6% retention, 26.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Greenheck maintains 31 active ENERGY STAR blowers; SP-AP0511W-1 (series: Model SP Ceiling Fan, Direct Drive) (PD #2406839) gained qualification on 2023-01-13. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.3 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 81.5 kWh/yr (~$13.04/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

What attic duct routing preserves Greenheck SP-AP0511W-1 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Greenheck SP-AP0511W-1, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Greenheck SP-AP0511W-1 measure up on airflow and noise ratings?

Each row below breaks down Greenheck SP-AP0511W-1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-AP0511W-1 / Model SP Ceiling Fan, Direct Drive PD ID 2406839 (Qualified 2023-01-13)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (126.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Greenheck SP-AP0511W-1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Greenheck SP-AP0511W-1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 126 sq ft1 CFM/sq ft @ 126.1 CFM
Tall Bath (9-ft Ceiling)Up to 112 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 76 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.4 kWh/yr (~$0.54/yr)9.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.281.5 kWh/yr (~$13.04/yr)9.3 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Greenheck SP-AP0511W-1?

Compare Greenheck SP-AP0511W-1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter

Can you size Greenheck SP-AP0511W-1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Greenheck SP-AP0511W-1 verified capacity.

Who should not install Greenheck SP-AP0511W-1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Greenheck SP-AP0511W-1 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 126.1 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around ENERGY STAR sones up to 126 sq ft
  • Primary match: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Greenheck SP-AP0511W-1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Greenheck SP-AP0511W-1.

How does Greenheck SP-AP0511W-1 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Greenheck SP-AP0511W-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Greenheck SP-AP0511W-1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Greenheck SP-AP0511W-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-AP0511W-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-AP0511W-1?

Greenheck SP-AP0511W-1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-AP0511W-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-AP0511W-1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Greenheck SP-AP0511W-1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-AP0511W-1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Greenheck SP-AP0511W-1 undersized or poorly matched for a bath renovation?

Skip Greenheck SP-AP0511W-1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Greenheck SP-AP0511W-1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Greenheck SP-AP0511W-1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories