In EPA dataset 8dv7-nngq, Greenheck SP-AP0511W-1 tests at 110 CFM free discharge (128.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 128 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-AP0511W-1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 128.3 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.4 CFM/W (#171/1,145)
- Static Retention
- 116.6% @ 0.25"
- Motor Draw
- 10.6 W (3.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Greenheck SP-AP0511W-1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Greenheck SP-AP0511W-1 (EPA filing PD #2406840) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 128.3 CFM out of 110 CFM (116.6% retention, 28.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Greenheck's 31-unit lineup, SP-AP0511W-1 (series: Model SP Ceiling Fan, Direct Drive) carries PD #2406840 dating to 2023-01-13. Lighting kit: No. At 10.4 CFM/W (#171 of 1,145, top 15.2% of 1,145 rated models, more efficient than 84.8% of rated models, 5.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
Why avoid unvented attic termination with Greenheck SP-AP0511W-1?
Under ASHRAE 62.2 best practice, Greenheck SP-AP0511W-1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Greenheck SP-AP0511W-1?
Before cutting ceiling drywall or sizing attic transitions for Greenheck SP-AP0511W-1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-AP0511W-1 / Model SP Ceiling Fan, Direct Drive | PD ID 2406840 (Qualified 2023-01-13) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (128.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Greenheck SP-AP0511W-1?
Bathroom ventilation sizing below maps Greenheck SP-AP0511W-1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 128 sq ft | 1 CFM/sq ft @ 128.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 114 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 78 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.9 kWh/yr (~$14.86/yr) | 10.6 W x 8,760 hrs / 1,000 |
What peer models sit nearest Greenheck SP-AP0511W-1 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Greenheck SP-AP0511W-1.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
What percentage of room demand does Greenheck SP-AP0511W-1 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Greenheck SP-AP0511W-1 tested delivery.
Does Greenheck SP-AP0511W-1 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Greenheck SP-AP0511W-1 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 128.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around ENERGY STAR sones up to 128 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Greenheck SP-AP0511W-1?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Greenheck SP-AP0511W-1.
How many kWh per year does Greenheck SP-AP0511W-1 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Greenheck SP-AP0511W-1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Greenheck SP-AP0511W-1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-AP0511W-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck SP-AP0511W-1?
Greenheck SP-AP0511W-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck SP-AP0511W-1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-AP0511W-1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Greenheck SP-AP0511W-1 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-AP0511W-1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Greenheck SP-AP0511W-1 in a bathroom remodel?
Avoid specifying Greenheck SP-AP0511W-1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Greenheck SP-AP0511W-1 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Greenheck SP-AP0511W-1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Greenheck SP-AP0511W-1 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Greenheck SP-AP0511W-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)