Rated for 110 CFM open-air (122.4 CFM at 0.25 in. w.g.), Greenheck SP-AP0511WL omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 122 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-AP0511WL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 122.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.6 CFM/W (#206/1,145)
- Static Retention
- 111.3% @ 0.25"
- Motor Draw
- 11.5 W (4.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Greenheck SP-AP0511WL vs. 1,145-Model ENERGY STAR Benchmarks show?
Greenheck SP-AP0511WL (EPA filing PD #4667654) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 122.4 CFM out of 110 CFM (111.3% retention, 23.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #4667654 verifies SP-AP0511WL (series: Model SP Ceiling Fan, Direct Drive) under Greenheck (31 listed models, qualified 2026-07-08). Lighting kit: Yes. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
How do flex elbows choke Greenheck SP-AP0511WL at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Greenheck SP-AP0511WL moving full rated CFM.
Does Greenheck SP-AP0511WL meet residential exhaust fan code specs?
Inspect Greenheck SP-AP0511WL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-AP0511WL / Model SP Ceiling Fan, Direct Drive | PD ID 4667654 (Qualified 2026-07-08) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (122.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Greenheck SP-AP0511WL airflow output?
Annual electricity figures and room square-footage ceilings below reflect Greenheck SP-AP0511WL tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 122 sq ft | 1 CFM/sq ft @ 122.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 108 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 72 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 100.7 kWh/yr (~$16.11/yr) | 11.5 W x 8,760 hrs / 1,000 |
Which competing models share Greenheck SP-AP0511WL airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
How much airflow margin does Greenheck SP-AP0511WL give your bath?
Run a quick local room-volume check for Greenheck SP-AP0511WL by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Greenheck SP-AP0511WL?
Match Greenheck SP-AP0511WL directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 72 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 122 sq ft with 8-ft ceilings (108 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Greenheck SP-AP0511WL?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Greenheck SP-AP0511WL.
Where does Greenheck SP-AP0511WL run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Greenheck SP-AP0511WL.
What happens to Greenheck SP-AP0511WL CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Greenheck SP-AP0511WL moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Greenheck SP-AP0511WL sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Greenheck SP-AP0511WL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Greenheck SP-AP0511WL cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Greenheck SP-AP0511WL 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Greenheck SP-AP0511WL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-AP0511WL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck SP-AP0511WL?
Greenheck SP-AP0511WL features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck SP-AP0511WL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-AP0511WL's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Greenheck SP-AP0511WL ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-AP0511WL covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)