Greenheck SP-AP0511WL Exhaust Fan Specifications

ENERGY STAR PD #4667654 · Bathroom/Utility Room · Qualified 2026-07-08
Verified Specification Summary

Rated for 110 CFM open-air (122.4 CFM at 0.25 in. w.g.), Greenheck SP-AP0511WL omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 122 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-AP0511WL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 122.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.6 CFM/W (#206/1,145)
Static Retention
111.3% @ 0.25"
Motor Draw
11.5 W (4.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-AP0511WL vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-AP0511WL (EPA filing PD #4667654) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 122.4 CFM out of 110 CFM (111.3% retention, 23.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4667654 verifies SP-AP0511WL (series: Model SP Ceiling Fan, Direct Drive) under Greenheck (31 listed models, qualified 2026-07-08). Lighting kit: Yes. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

How do flex elbows choke Greenheck SP-AP0511WL at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Greenheck SP-AP0511WL moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Greenheck SP-AP0511WL meet residential exhaust fan code specs?

Inspect Greenheck SP-AP0511WL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-AP0511WL / Model SP Ceiling Fan, Direct Drive PD ID 4667654 (Qualified 2026-07-08)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (122.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Greenheck SP-AP0511WL airflow output?

Annual electricity figures and room square-footage ceilings below reflect Greenheck SP-AP0511WL tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Greenheck SP-AP0511WL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 122 sq ft1 CFM/sq ft @ 122.4 CFM
Tall Bath (9-ft Ceiling)Up to 108 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 72 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.2 kWh/yr (~$0.67/yr)11.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2100.7 kWh/yr (~$16.11/yr)11.5 W x 8,760 hrs / 1,000

Which competing models share Greenheck SP-AP0511WL airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does Greenheck SP-AP0511WL give your bath?

Run a quick local room-volume check for Greenheck SP-AP0511WL by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Greenheck SP-AP0511WL?

Match Greenheck SP-AP0511WL directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 72 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 122 sq ft with 8-ft ceilings (108 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about Greenheck SP-AP0511WL?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Greenheck SP-AP0511WL.

Where does Greenheck SP-AP0511WL run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Greenheck SP-AP0511WL.

What happens to Greenheck SP-AP0511WL CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Greenheck SP-AP0511WL moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Greenheck SP-AP0511WL sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Greenheck SP-AP0511WL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Greenheck SP-AP0511WL cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Greenheck SP-AP0511WL 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Greenheck SP-AP0511WL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-AP0511WL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-AP0511WL?

Greenheck SP-AP0511WL features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-AP0511WL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-AP0511WL's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Greenheck SP-AP0511WL ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-AP0511WL covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories