Greenheck SP-AP0511WL-1 Exhaust Fan Specifications

ENERGY STAR PD #4667661 · Bathroom/Utility Room · Qualified 2026-07-08
Verified Specification Summary

Tested under HVI protocols, the Greenheck SP-AP0511WL-1 exhaust unit achieves 110 CFM at 0.1 in. w.g. (123.9 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 8.7 CFM/W efficacy, covering standard baths up to 123 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-AP0511WL-1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 123.9 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.7 CFM/W (#306/1,145)
Static Retention
112.6% @ 0.25"
Motor Draw
12.6 W (4.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-AP0511WL-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-AP0511WL-1 (EPA filing PD #4667661) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 123.9 CFM out of 110 CFM (112.6% retention, 24.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places SP-AP0511WL-1 (series: Model SP Ceiling Fan, Direct Drive) (PD #4667661) among 31 Greenheck entries qualified through 2026-07-08. Lighting kit: Yes. At 8.7 CFM/W (#306 of 1,145, top 27.6% of 1,145 rated models, more efficient than 72.4% of rated models, 4.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.6 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 110.4 kWh/yr (~$17.66/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

What attic duct routing preserves Greenheck SP-AP0511WL-1 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Greenheck SP-AP0511WL-1, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Greenheck SP-AP0511WL-1 measure up on airflow and noise ratings?

Each row below breaks down Greenheck SP-AP0511WL-1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-AP0511WL-1 / Model SP Ceiling Fan, Direct Drive PD ID 4667661 (Qualified 2026-07-08)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (123.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Greenheck SP-AP0511WL-1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Greenheck SP-AP0511WL-1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 123 sq ft1 CFM/sq ft @ 123.9 CFM
Tall Bath (9-ft Ceiling)Up to 110 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 73 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.6 kWh/yr (~$0.74/yr)12.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2110.4 kWh/yr (~$17.66/yr)12.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Greenheck SP-AP0511WL-1?

Compare Greenheck SP-AP0511WL-1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Can you size Greenheck SP-AP0511WL-1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Greenheck SP-AP0511WL-1 verified capacity.

Which bath layouts should avoid specifying Greenheck SP-AP0511WL-1?

Match Greenheck SP-AP0511WL-1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 123.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 123 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Greenheck SP-AP0511WL-1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Greenheck SP-AP0511WL-1.

Where does Greenheck SP-AP0511WL-1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Greenheck SP-AP0511WL-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Greenheck SP-AP0511WL-1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Greenheck SP-AP0511WL-1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Greenheck SP-AP0511WL-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-AP0511WL-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-AP0511WL-1?

Greenheck SP-AP0511WL-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-AP0511WL-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-AP0511WL-1's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Greenheck SP-AP0511WL-1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-AP0511WL-1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Greenheck SP-AP0511WL-1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Greenheck SP-AP0511WL-1.

What happens to Greenheck SP-AP0511WL-1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Greenheck SP-AP0511WL-1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.