In EPA dataset 8dv7-nngq, KOHLER 34455-NA tests at 130 CFM free discharge (103.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 3.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 103 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34455-NA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 103.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 79.8% @ 0.25"
- Motor Draw
- 35.1 W (12.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does KOHLER 34455-NA vs. 1,145-Model ENERGY STAR Benchmarks show?
KOHLER 34455-NA (EPA filing PD #4528864) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 130 CFM open-air to 103.7 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside KOHLER's 32-unit lineup, 34455-NA (series: 34455) carries PD #4528864 dating to 2026-01-28. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.1 watts, about 12.8 kWh/yr (~$2.05/yr at $0.16/kWh) for 1 hr/day shower timers or 307.5 kWh/yr (~$49.20/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).
Why avoid unvented attic termination with KOHLER 34455-NA?
Under ASHRAE 62.2 best practice, KOHLER 34455-NA needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern KOHLER 34455-NA?
Before cutting ceiling drywall or sizing attic transitions for KOHLER 34455-NA, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | KOHLER (32 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 34455-NA / 34455 | PD ID 4528864 (Qualified 2026-01-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (103.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit KOHLER 34455-NA?
Bathroom ventilation sizing below maps KOHLER 34455-NA motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.8 kWh/yr (~$2.05/yr) | 35.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 307.5 kWh/yr (~$49.20/yr) | 35.1 W x 8,760 hrs / 1,000 |
What peer models sit nearest KOHLER 34455-NA in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to KOHLER 34455-NA.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Greenheck SP-B110ES | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| KORA SBF110N | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |
What percentage of room demand does KOHLER 34455-NA cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against KOHLER 34455-NA tested delivery.
Which bath layouts should avoid specifying KOHLER 34455-NA?
Match KOHLER 34455-NA directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 103.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around ENERGY STAR sones up to 103 sq ft
- Optimal use: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for KOHLER 34455-NA?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing KOHLER 34455-NA.
What bathroom square footage can KOHLER 34455-NA ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34455-NA covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does KOHLER 34455-NA run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with KOHLER 34455-NA.
What happens to KOHLER 34455-NA CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, KOHLER 34455-NA moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does KOHLER 34455-NA sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, KOHLER 34455-NA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does KOHLER 34455-NA cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running KOHLER 34455-NA 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can KOHLER 34455-NA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34455-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing KOHLER 34455-NA?
KOHLER 34455-NA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change KOHLER 34455-NA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34455-NA's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)