Tested under HVI protocols, the KOHLER 34455 exhaust unit achieves 130 CFM at 0.1 in. w.g. (103.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 3.7 CFM/W efficacy, covering standard baths up to 103 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34455 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 103.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 79.8% @ 0.25"
- Motor Draw
- 35.1 W (12.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does KOHLER 34455 vs. 1,145-Model ENERGY STAR Benchmarks show?
KOHLER 34455 (EPA filing PD #3626822) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 130 CFM open-air to 103.7 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
KOHLER maintains 32 active ENERGY STAR blowers; 34455 (series: ATMO) (PD #3626822) gained qualification on 2024-08-30. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.1 watts, about 12.8 kWh/yr (~$2.05/yr at $0.16/kWh) for 1 hr/day shower timers or 307.5 kWh/yr (~$49.20/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).
What attic duct routing preserves KOHLER 34455 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on KOHLER 34455, preventing premature peeling paint and mold growth.
How does KOHLER 34455 measure up on airflow and noise ratings?
Each row below breaks down KOHLER 34455 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | KOHLER (32 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 34455 / ATMO | PD ID 3626822 (Qualified 2024-08-30) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (103.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect KOHLER 34455 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.8 kWh/yr (~$2.05/yr) | 35.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 307.5 kWh/yr (~$49.20/yr) | 35.1 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against KOHLER 34455?
Compare KOHLER 34455 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Greenheck SP-B110ES | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| KORA SBF110N | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |
Can you size KOHLER 34455 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against KOHLER 34455 verified capacity.
Does KOHLER 34455 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying KOHLER 34455 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 103.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around ENERGY STAR sones up to 103 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to KOHLER 34455?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for KOHLER 34455.
What acoustic sone tier does KOHLER 34455 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., KOHLER 34455 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does KOHLER 34455 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, KOHLER 34455 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can KOHLER 34455 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34455's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing KOHLER 34455?
KOHLER 34455 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change KOHLER 34455's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34455's safe coverage footprint from 50 sq ft to 44 sq ft.
Does KOHLER 34455 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34455 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install KOHLER 34455 in a bathroom remodel?
Avoid specifying KOHLER 34455 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut KOHLER 34455 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, KOHLER 34455 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)