KOHLER K-34456 Exhaust Fan Specifications

ENERGY STAR PD #4528846 · Bathroom/Utility Room · Qualified 2026-01-28
Verified Specification Summary

In EPA dataset 8dv7-nngq, KOHLER K-34456 tests at 130 CFM free discharge (106 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 106 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER K-34456 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / 106 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
81.5% @ 0.25"
Motor Draw
33.3 W (12.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KOHLER K-34456 vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER K-34456 (EPA filing PD #4528846) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 106 CFM at 0.25 in. w.g. (81.5% retention, 6.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places K-34456 (series: 34456) (PD #4528846) among 32 KOHLER entries qualified through 2026-01-28. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).

Why avoid unvented attic termination with KOHLER K-34456?

Under ASHRAE 62.2 best practice, KOHLER K-34456 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern KOHLER K-34456?

Before cutting ceiling drywall or sizing attic transitions for KOHLER K-34456, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KOHLER (32 models) ENERGY STAR Certified Partner
Model Number & Series K-34456 / 34456 PD ID 4528846 (Qualified 2026-01-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit KOHLER K-34456?

Bathroom ventilation sizing below maps KOHLER K-34456 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for KOHLER K-34456
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.2 kWh/yr (~$1.95/yr)33.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2291.7 kWh/yr (~$46.67/yr)33.3 W x 8,760 hrs / 1,000

What peer models sit nearest KOHLER K-34456 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to KOHLER K-34456.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones 4.0 CFM/W 6 in. diameter
KORA SBF110N 119.2 / N/A CFM 1.6 sones 3.5 CFM/W 4 in. diameter

What percentage of room demand does KOHLER K-34456 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against KOHLER K-34456 tested delivery.

When does KOHLER K-34456 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering KOHLER K-34456.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 106 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 106 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for KOHLER K-34456?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing KOHLER K-34456.

Does running KOHLER K-34456 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of KOHLER K-34456 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can KOHLER K-34456 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER K-34456's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KOHLER K-34456?

KOHLER K-34456 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KOHLER K-34456's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER K-34456's safe coverage footprint from 50 sq ft to 44 sq ft.

Is KOHLER K-34456 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), KOHLER K-34456 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than KOHLER K-34456?

Do not force KOHLER K-34456 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does KOHLER K-34456 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, KOHLER K-34456 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will KOHLER K-34456 disturb adjacent bedrooms during night use?

Acoustic measurement places KOHLER K-34456 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.