Tested under HVI protocols, the Nutone 744RNL exhaust unit achieves 80 CFM at 0.1 in. w.g. (65.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 2.9 CFM/W efficacy, covering standard baths up to 65 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone 744RNL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 65.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 2.9 CFM/W (#1,132/1,145)
- Static Retention
- 81.8% @ 0.25"
- Motor Draw
- 27.6 W (10.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Nutone 744RNL vs. 1,145-Model ENERGY STAR Benchmarks show?
Nutone 744RNL (EPA filing PD #2335151) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 65.4 CFM at 0.25 in. w.g. (81.8% retention, 5.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Nutone registers 16 certified models, with SKU 744RNL (series: RECESSED FAN) (PD #2335151) certified since 2019-03-08. Lighting kit: Yes. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.6 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 241.8 kWh/yr (~$38.69/yr) continuously. Closest competing matches include HomeWerks Worldwide 7140-80-G3 (80.0 CFM) and S&P PCV80 (80.0 CFM).
What attic duct routing preserves Nutone 744RNL CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Nutone 744RNL, preventing premature peeling paint and mold growth.
How does Nutone 744RNL measure up on airflow and noise ratings?
Each row below breaks down Nutone 744RNL certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Nutone (16 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 744RNL / RECESSED FAN | PD ID 2335151 (Qualified 2019-03-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (65.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Nutone 744RNL CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 65 sq ft | 1 CFM/sq ft @ 65.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 58 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.1 kWh/yr (~$1.62/yr) | 27.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 241.8 kWh/yr (~$38.69/yr) | 27.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Nutone 744RNL?
Compare Nutone 744RNL side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| HomeWerks Worldwide 7140-80-G3 | 80 / 58.8 CFM | 1.5 sones | 3.4 CFM/W | 4 in. diameter |
| S&P PCV80 | 80 / 60.8 CFM | 1.5 sones | 3.4 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7140-80 | 80 / 57.2 CFM | 1.5 sones | 3.5 CFM/W | 4 in. diameter |
| Wintek BPT13B-80-L4 | 80 / 57.2 CFM | 1.5 sones | 3.5 CFM/W | 4 in. diameter |
| PROJECT SOURCE 8781-80-PS | 80 / 61.2 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |
Can you size Nutone 744RNL for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Nutone 744RNL verified capacity.
Does Nutone 744RNL suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Nutone 744RNL for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 65.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around ENERGY STAR sones up to 65 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Nutone 744RNL?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Nutone 744RNL.
Does Nutone 744RNL pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Nutone 744RNL easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Nutone 744RNL in a bathroom remodel?
Avoid specifying Nutone 744RNL in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Nutone 744RNL airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Nutone 744RNL achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Nutone 744RNL occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Nutone 744RNL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Nutone 744RNL add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Nutone 744RNL averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Nutone 744RNL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone 744RNL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Nutone 744RNL?
Nutone 744RNL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Nutone 744RNL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone 744RNL's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)