Ortech ODD-110S Exhaust Fan Specifications

ENERGY STAR PD #4439148 · Bathroom/Utility Room · Qualified 2025-06-20
Verified Specification Summary

The Ortech ODD-110S (ODD-110S) moves 113 CFM at 0.1 in. w.g. (97.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 11.8 CFM/W efficacy, sizing bathrooms up to 97 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-110S Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
113 / 97.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.8 CFM/W (#90/1,145)
Static Retention
86.3% @ 0.25"
Motor Draw
9.6 W (3.5 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODD-110S vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech ODD-110S (EPA filing PD #4439148) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.5 CFM out of 113 CFM (86.3% retention, 1.4 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Ortech's 27-unit lineup, ODD-110S (series: ODD-110S) carries PD #4439148 dating to 2025-06-20. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.6 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 84.1 kWh/yr (~$13.46/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

How does duct geometry alter Ortech ODD-110S static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Ortech ODD-110S?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Ortech ODD-110S alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODD-110S / ODD-110S PD ID 4439148 (Qualified 2025-06-20)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (97.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Ortech ODD-110S ventilate safely?

Sizing outputs below convert Ortech ODD-110S tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Ortech ODD-110S
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 97 sq ft1 CFM/sq ft @ 97.5 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 47 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.5 kWh/yr (~$0.56/yr)9.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.284.1 kWh/yr (~$13.46/yr)9.6 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Ortech ODD-110S closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter

Will Ortech ODD-110S clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Ortech ODD-110S satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

What plumbing or duct constraints rule out Ortech ODD-110S?

Compare where Ortech ODD-110S excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 47 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 97 sq ft with 8-ft ceilings (86 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Ortech ODD-110S?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Ortech ODD-110S.

Is Ortech ODD-110S quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Ortech ODD-110S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Ortech ODD-110S energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Ortech ODD-110S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-110S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODD-110S?

Ortech ODD-110S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODD-110S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-110S's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Ortech ODD-110S serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Ortech ODD-110S supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Ortech ODD-110S for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Ortech ODD-110S lacks adequate reserve.

How does Ortech ODD-110S handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Ortech ODD-110S yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories