Skip to main content
Grant Estimator

Ortech ODD-300-3 Exhaust Fan Specifications

ENERGY STAR PD #4005669 · Bathroom/Utility Room · Qualified 2025-03-21
Verified Specification Summary

Homeowners specifying Ortech ODD-300-3 gain 292 CFM at 0.1 in. w.g. (263.2 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 6.5 CFM/W efficacy, venting bathrooms up to 263 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-300-3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
292 / 263.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
6.5 CFM/W (#436/1,145)
Static Retention
90.1% @ 0.25"
Motor Draw
44.9 W (16.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODD-300-3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech ODD-300-3 (EPA filing PD #4005669) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 263.2 CFM out of 292 CFM (90.1% retention, 2.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Ortech registers 27 certified models, with SKU ODD-300-3 (series: ODD-300-3) (PD #4005669) certified since 2025-03-21. Lighting kit: No. At 6.5 CFM/W (#436 of 1,145, top 38.2% of 1,145 rated models, more efficient than 61.8% of rated models, 1.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 44.9 watts, about 16.4 kWh/yr (~$2.62/yr at $0.16/kWh) for 1 hr/day shower timers or 393.3 kWh/yr (~$62.93/yr) continuously. Closest competing matches include Delta Pro300 (300.0 CFM) and S&P PCD300IL (300.0 CFM).

Which exterior damper path suits Ortech ODD-300-3 best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Ortech ODD-300-3 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Ortech ODD-300-3 acoustic and static metrics stand?

Compare Ortech ODD-300-3 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODD-300-3 / ODD-300-3 PD ID 4005669 (Qualified 2025-03-21)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (263.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Ortech ODD-300-3 handle taller ceilings or walk-in tub steam?

Evaluate how Ortech ODD-300-3 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Ortech ODD-300-3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 263 sq ft1 CFM/sq ft @ 263.2 CFM
Tall Bath (9-ft Ceiling)Up to 233 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 213 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)16.4 kWh/yr (~$2.62/yr)44.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2393.3 kWh/yr (~$62.93/yr)44.9 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Ortech ODD-300-3?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta Pro300 300 / 271.3 CFM 2.0 sones 7.4 CFM/W 6 in. diameter
S&P PCD300IL 300 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Panasonic FV-30VQ3 280 / 254.4 CFM 2.0 sones 4.4 CFM/W 6 in. diameter
Fantech FR 150 (411334) 280 / N/A CFM Unpublished 4.3 CFM/W 6 in. diameter
Ortech ODDIN-300 300 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter

Is Ortech ODD-300-3 sized right for your shower or tub room?

Check whether Ortech ODD-300-3 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Ortech ODD-300-3 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Ortech ODD-300-3 for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 213 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 263.2 CFM net static output
  • Best application: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Ortech ODD-300-3?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Ortech ODD-300-3.

Does duct resistance cut Ortech ODD-300-3 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Ortech ODD-300-3 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Ortech ODD-300-3 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Ortech ODD-300-3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Ortech ODD-300-3 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Ortech ODD-300-3 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Ortech ODD-300-3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-300-3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODD-300-3?

Ortech ODD-300-3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODD-300-3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-300-3's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Ortech ODD-300-3 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Ortech ODD-300-3 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Ortech ODD-300-3 in a bathroom remodel?

Avoid specifying Ortech ODD-300-3 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories