Skip to main content
Grant Estimator

Ortech ODDIN-300 Exhaust Fan Specifications

ENERGY STAR PD #4656694 · In-line (single-port) · Qualified 2026-04-22
Verified Specification Summary

In EPA dataset 8dv7-nngq, Ortech ODDIN-300 tests at 300 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 300 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODDIN-300 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
300 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.9 CFM/W (#519/1,145)
Static Retention
0.1" test only
Motor Draw
61.2 W (22.3 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODDIN-300 vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech ODDIN-300 (EPA filing PD #4656694) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 300 CFM (#16 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Ortech registers 27 certified models, with SKU ODDIN-300 (series: ODDIN) (PD #4656694) certified since 2026-04-22. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 61.2 watts, about 22.3 kWh/yr (~$3.57/yr at $0.16/kWh) for 1 hr/day shower timers or 536.1 kWh/yr (~$85.78/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

Why avoid unvented attic termination with Ortech ODDIN-300?

Under ASHRAE 62.2 best practice, Ortech ODDIN-300 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Ortech ODDIN-300?

Before cutting ceiling drywall or sizing attic transitions for Ortech ODDIN-300, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODDIN-300 / ODDIN PD ID 4656694 (Qualified 2026-04-22)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (300 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Ortech ODDIN-300?

Bathroom ventilation sizing below maps Ortech ODDIN-300 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Ortech ODDIN-300
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 300 sq ft1 CFM/sq ft @ 300 CFM
Tall Bath (9-ft Ceiling)Up to 266 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 250 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)22.3 kWh/yr (~$3.57/yr)61.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2536.1 kWh/yr (~$85.78/yr)61.2 W x 8,760 hrs / 1,000

What peer models sit nearest Ortech ODDIN-300 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Ortech ODDIN-300.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200 200 / N/A CFM Unpublished 5.3 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter

What percentage of room demand does Ortech ODDIN-300 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Ortech ODDIN-300 tested delivery.

Which bath layouts should avoid specifying Ortech ODDIN-300?

Match Ortech ODDIN-300 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 300 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 300 sq ft
  • Optimal use: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Ortech ODDIN-300?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Ortech ODDIN-300.

What bathroom square footage can Ortech ODDIN-300 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Ortech ODDIN-300 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Ortech ODDIN-300 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Ortech ODDIN-300.

What happens to Ortech ODDIN-300 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Ortech ODDIN-300 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Ortech ODDIN-300 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Ortech ODDIN-300 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Ortech ODDIN-300 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Ortech ODDIN-300 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Ortech ODDIN-300 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODDIN-300's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODDIN-300?

Ortech ODDIN-300 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODDIN-300's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODDIN-300's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories