S&P PCD300IL Exhaust Fan Specifications

ENERGY STAR PD #4514277 · In-line (single-port) · Qualified 2025-11-07
Verified Specification Summary

Rated for 300 CFM open-air (unpublished 0.25 in. w.g. output), S&P PCD300IL omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 300 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCD300IL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
300 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.9 CFM/W (#519/1,145)
Static Retention
0.1" test only
Motor Draw
61.2 W (22.3 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PCD300IL vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P PCD300IL (EPA filing PD #4514277) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 300 CFM (#16 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

S&P maintains 29 active ENERGY STAR blowers; PCD300IL (series: PCDIL) (PD #4514277) gained qualification on 2025-11-07. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 61.2 watts, about 22.3 kWh/yr (~$3.57/yr at $0.16/kWh) for 1 hr/day shower timers or 536.1 kWh/yr (~$85.78/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

How do flex elbows choke S&P PCD300IL at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps S&P PCD300IL moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does S&P PCD300IL meet residential exhaust fan code specs?

Inspect S&P PCD300IL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PCD300IL / PCDIL PD ID 4514277 (Qualified 2025-11-07)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (300 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match S&P PCD300IL airflow output?

Annual electricity figures and room square-footage ceilings below reflect S&P PCD300IL tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for S&P PCD300IL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 300 sq ft1 CFM/sq ft @ 300 CFM
Tall Bath (9-ft Ceiling)Up to 266 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 250 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)22.3 kWh/yr (~$3.57/yr)61.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2536.1 kWh/yr (~$85.78/yr)61.2 W x 8,760 hrs / 1,000

Which competing models share S&P PCD300IL airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200 200 / N/A CFM Unpublished 5.3 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter

How much airflow margin does S&P PCD300IL give your bath?

Run a quick local room-volume check for S&P PCD300IL by entering square footage and ceiling height to spot under-vented steam risks early.

When does S&P PCD300IL fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering S&P PCD300IL.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 250 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 300 sq ft with 8-ft ceilings (266 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about S&P PCD300IL?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to S&P PCD300IL.

How much airflow does S&P PCD300IL retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, S&P PCD300IL produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will S&P PCD300IL disturb adjacent bedrooms during night use?

Acoustic measurement places S&P PCD300IL at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running S&P PCD300IL continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of S&P PCD300IL draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can S&P PCD300IL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCD300IL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PCD300IL?

S&P PCD300IL features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PCD300IL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCD300IL's safe coverage footprint from 50 sq ft to 44 sq ft.

Is S&P PCD300IL code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), S&P PCD300IL clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than S&P PCD300IL?

Do not force S&P PCD300IL into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.