Skip to main content
Grant Estimator

Broan L300E Exhaust Fan Specifications

ENERGY STAR PD #2405821 · Bathroom/Utility Room · Qualified 2022-12-09
Verified Specification Summary

Homeowners specifying Broan L300E gain 310 CFM at 0.1 in. w.g. (285.9 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy, venting bathrooms up to 285 sq ft cleanly through 8 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan L300E Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
310 / 285.9 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
92.2% @ 0.25"
Motor Draw
70.5 W (25.7 kWh/yr)
Duct & Tier
8 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan L300E vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan L300E (EPA filing PD #2405821) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 285.9 CFM out of 310 CFM (92.2% retention, 4.5 pts higher retention than the 87.7% median). Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan maintains 207 active ENERGY STAR blowers; L300E (series: LIGHT COMMERCIAL) (PD #2405821) gained qualification on 2022-12-09. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 70.5 watts, about 25.7 kWh/yr (~$4.11/yr at $0.16/kWh) for 1 hr/day shower timers or 617.6 kWh/yr (~$98.82/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

Which exterior damper path suits Broan L300E best?

Exterior roof or wall damper termination paired with insulated 8 in. diameter metal pipe prevents condensation buildup around Broan L300E housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan L300E acoustic and static metrics stand?

Compare Broan L300E published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series L300E / LIGHT COMMERCIAL PD ID 2405821 (Qualified 2022-12-09)
Duct Connection 8 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (285.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Broan L300E handle taller ceilings or walk-in tub steam?

Evaluate how Broan L300E scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan L300E
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 285 sq ft1 CFM/sq ft @ 285.9 CFM
Tall Bath (9-ft Ceiling)Up to 254 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 235 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)25.7 kWh/yr (~$4.11/yr)70.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2617.6 kWh/yr (~$98.82/yr)70.5 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan L300E?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200 200 / N/A CFM Unpublished 5.3 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter

Is Broan L300E sized right for your shower or tub room?

Check whether Broan L300E clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Broan L300E?

Compare where Broan L300E excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 235 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 285.9 CFM net static output
  • Suited to: Collar pairs with 8 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan L300E?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan L300E.

Can Broan L300E serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan L300E supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Broan L300E for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan L300E lacks adequate reserve.

How does Broan L300E handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan L300E yields unlisted 0.25 in. w.g. backpressure figures, so smooth 8 in. diameter rigid metal ducting protects real exhaust.

Is Broan L300E quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Broan L300E produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan L300E energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan L300E pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan L300E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan L300E?

Broan L300E features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan L300E's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan L300E's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories