Skip to main content
Grant Estimator

Panasonic FV-0511VFL1K Exhaust Fan Specifications

ENERGY STAR PD #2382168 · Bathroom/Utility Room · Qualified 2021-06-04
Verified Specification Summary

Homeowners specifying Panasonic FV-0511VFL1K gain 110 CFM at 0.1 in. w.g. (90.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 6.4 CFM/W efficacy, venting bathrooms up to 90 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFL1K Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 90.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
6.4 CFM/W (#438/1,145)
Static Retention
81.9% @ 0.25"
Motor Draw
17.2 W (6.3 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VFL1K vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFL1K (EPA filing PD #2382168) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 90.1 CFM at 0.25 in. w.g. (81.9% retention, 5.8 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places FV-0511VFL1K (series: WhisperFit DC) (PD #2382168) among 92 Panasonic entries qualified through 2021-06-04. Lighting kit: Yes. At 6.4 CFM/W (#438 of 1,145, top 38.8% of 1,145 rated models, more efficient than 61.2% of rated models, 1.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7115-01 (100.0 CFM).

Which exterior damper path suits Panasonic FV-0511VFL1K best?

Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Panasonic FV-0511VFL1K housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Panasonic FV-0511VFL1K acoustic and static metrics stand?

Compare Panasonic FV-0511VFL1K published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VFL1K / WhisperFit DC PD ID 2382168 (Qualified 2021-06-04)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (90.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Panasonic FV-0511VFL1K handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic FV-0511VFL1K scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFL1K
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 90 sq ft1 CFM/sq ft @ 90.1 CFM
Tall Bath (9-ft Ceiling)Up to 80 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 40 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.3 kWh/yr (~$1.01/yr)17.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2150.7 kWh/yr (~$24.11/yr)17.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Panasonic FV-0511VFL1K?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech 7115-01 100 / 95.4 CFM 1.5 sones 6.5 CFM/W 4 in. diameter
Tech Drive TD-BF-10 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
Tech Drive TD-BF-10-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
VENTECHLATION BPT14-24TG-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter

Is Panasonic FV-0511VFL1K sized right for your shower or tub room?

Check whether Panasonic FV-0511VFL1K clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying Panasonic FV-0511VFL1K?

Match Panasonic FV-0511VFL1K directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 40 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 90.1 CFM net static output
  • Optimal use: Collar pairs with 3 in. diameter duct straight outdoors

Which code checks and cost facts matter for Panasonic FV-0511VFL1K?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic FV-0511VFL1K.

Where does Panasonic FV-0511VFL1K sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic FV-0511VFL1K produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Panasonic FV-0511VFL1K cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic FV-0511VFL1K 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Panasonic FV-0511VFL1K pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFL1K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VFL1K?

Panasonic FV-0511VFL1K features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VFL1K's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFL1K's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Panasonic FV-0511VFL1K ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFL1K covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Panasonic FV-0511VFL1K run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-0511VFL1K.

What happens to Panasonic FV-0511VFL1K CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic FV-0511VFL1K moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories