Skip to main content
Grant Estimator

Panasonic FV-0811RFC1 Exhaust Fan Specifications

ENERGY STAR PD #2405530 · Bathroom/Utility Room · Qualified 2022-12-09
Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV-0811RFC1 delivers 110 CFM free-air (111.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 111 sq ft (8-ft height) or 98 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0811RFC1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 111.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.5 CFM/W (#234/1,145)
Static Retention
101.1% @ 0.25"
Motor Draw
11.6 W (4.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0811RFC1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0811RFC1 (EPA filing PD #2405530) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.2 CFM out of 110 CFM (101.1% retention, 13.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Panasonic's 92-unit lineup, FV-0811RFC1 (series: Whisper Remodel Auto) carries PD #2405530 dating to 2022-12-09. Lighting kit: No. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

Why does rigid 4 in. diameter ducting protect Panasonic FV-0811RFC1 airflow?

Connecting Panasonic FV-0811RFC1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Panasonic FV-0811RFC1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-0811RFC1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0811RFC1 / Whisper Remodel Auto PD ID 2405530 (Qualified 2022-12-09)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (111.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Panasonic FV-0811RFC1?

Calculated coverage metrics translate Panasonic FV-0811RFC1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0811RFC1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 111 sq ft1 CFM/sq ft @ 111.2 CFM
Tall Bath (9-ft Ceiling)Up to 98 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 61 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.2 kWh/yr (~$0.67/yr)11.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2101.6 kWh/yr (~$16.26/yr)11.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Panasonic FV-0811RFC1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Panasonic FV-0811RFC1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-0811RFC1 percentage capacity without sending data.

What plumbing or duct constraints rule out Panasonic FV-0811RFC1?

Compare where Panasonic FV-0811RFC1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 61 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 111.2 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Panasonic FV-0811RFC1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-0811RFC1.

Is Panasonic FV-0811RFC1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Panasonic FV-0811RFC1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0811RFC1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0811RFC1?

Panasonic FV-0811RFC1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0811RFC1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0811RFC1's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Panasonic FV-0811RFC1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV-0811RFC1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Panasonic FV-0811RFC1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV-0811RFC1 lacks adequate reserve.

How does Panasonic FV-0811RFC1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV-0811RFC1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Panasonic FV-0811RFC1 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic FV-0811RFC1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories