Homeowners specifying Panasonic RG-R811LA gain 110 CFM at 0.1 in. w.g. (111.2 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 9.5 CFM/W efficacy, venting bathrooms up to 111 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-R811LA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 111.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.5 CFM/W (#234/1,145)
- Static Retention
- 101.1% @ 0.25"
- Motor Draw
- 11.6 W (4.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic RG-R811LA vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic RG-R811LA (EPA filing PD #2405783) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.2 CFM out of 110 CFM (101.1% retention, 13.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Panasonic RG-R811LA (series: Whisper Remodel) under PD #2405783 (92 models registered, 2022-12-09). Lighting kit: Yes. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
Which exterior damper path suits Panasonic RG-R811LA best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic RG-R811LA housings.
Where do Panasonic RG-R811LA acoustic and static metrics stand?
Compare Panasonic RG-R811LA published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-R811LA / Whisper Remodel | PD ID 2405783 (Qualified 2022-12-09) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (111.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Panasonic RG-R811LA handle taller ceilings or walk-in tub steam?
Evaluate how Panasonic RG-R811LA scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 111 sq ft | 1 CFM/sq ft @ 111.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 61 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 101.6 kWh/yr (~$16.26/yr) | 11.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Panasonic RG-R811LA?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Is Panasonic RG-R811LA sized right for your shower or tub room?
Check whether Panasonic RG-R811LA clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does Panasonic RG-R811LA fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic RG-R811LA.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 61 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 111.2 CFM net static output
- Target scenario: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Panasonic RG-R811LA?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic RG-R811LA.
Which bathroom layouts should pick a larger blower than Panasonic RG-R811LA?
Do not force Panasonic RG-R811LA into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Panasonic RG-R811LA retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Panasonic RG-R811LA produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Panasonic RG-R811LA disturb adjacent bedrooms during night use?
Acoustic measurement places Panasonic RG-R811LA at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Panasonic RG-R811LA continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Panasonic RG-R811LA draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Panasonic RG-R811LA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-R811LA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic RG-R811LA?
Panasonic RG-R811LA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic RG-R811LA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-R811LA's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Panasonic RG-R811LA code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-R811LA clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)