Homeowners specifying RadonAway RP140C gain 110 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 5.9 CFM/W efficacy, venting bathrooms up to 110 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside RadonAway RP140C Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.9 CFM/W (#460/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 18.6 W (6.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does RadonAway RP140C vs. 1,145-Model ENERGY STAR Benchmarks show?
RadonAway RP140C (EPA filing PD #4005524) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 110 CFM (#317 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside RadonAway's 1-unit lineup, RP140C (series: RP) carries PD #4005524 dating to 2025-03-21. Lighting kit: No. At 5.9 CFM/W (#460 of 1,145, top 40.2% of 1,145 rated models, more efficient than 59.8% of rated models, 1.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Tech Drive TD-BF-10 (110.0 CFM).
Which exterior damper path suits RadonAway RP140C best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around RadonAway RP140C housings.
Where do RadonAway RP140C acoustic and static metrics stand?
Compare RadonAway RP140C published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | RadonAway (1 model) | ENERGY STAR Certified Partner |
| Model Number & Series | RP140C / RP | PD ID 4005524 (Qualified 2025-03-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (110 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can RadonAway RP140C handle taller ceilings or walk-in tub steam?
Evaluate how RadonAway RP140C scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110 CFM |
| Tall Bath (9-ft Ceiling) | Up to 97 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.9 kWh/yr (~$26.06/yr) | 18.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near RadonAway RP140C?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TG-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TGHS | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
Is RadonAway RP140C sized right for your shower or tub room?
Check whether RadonAway RP140C clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
What plumbing or duct constraints rule out RadonAway RP140C?
Compare where RadonAway RP140C excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 60 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 110 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for RadonAway RP140C?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to RadonAway RP140C.
Why might a contractor swap RadonAway RP140C for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, RadonAway RP140C lacks adequate reserve.
How does RadonAway RP140C handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., RadonAway RP140C yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is RadonAway RP140C quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, RadonAway RP140C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is RadonAway RP140C energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can RadonAway RP140C pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from RadonAway RP140C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing RadonAway RP140C?
RadonAway RP140C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change RadonAway RP140C's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing RadonAway RP140C's safe coverage footprint from 50 sq ft to 44 sq ft.
Can RadonAway RP140C serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: RadonAway RP140C supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)