RAB CEP10SNL Exhaust Fan Specifications

ENERGY STAR PD #4713814 · Bathroom/Utility Room · Qualified 2026-10-07
Verified Specification Summary

Rated for 110 CFM open-air (100.8 CFM at 0.25 in. w.g.), RAB CEP10SNL omits a published 0.1-inch sone rating and delivers 4.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 100 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside RAB CEP10SNL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 100.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
91.6% @ 0.25"
Motor Draw
26.8 W (9.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does RAB CEP10SNL vs. 1,145-Model ENERGY STAR Benchmarks show?

RAB CEP10SNL (EPA filing PD #4713814) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.8 CFM out of 110 CFM (91.6% retention, 3.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: RAB registers 3 certified models, with SKU CEP10SNL (series: Bathroom Exhaust Fans) (PD #4713814) certified since 2026-10-07. Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include Broan AER110RGBL (110.0 CFM) and Tech Drive TD-BF-07-plus (110.0 CFM).

How do flex elbows choke RAB CEP10SNL at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps RAB CEP10SNL moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does RAB CEP10SNL meet residential exhaust fan code specs?

Inspect RAB CEP10SNL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share RAB (3 models) ENERGY STAR Certified Partner
Model Number & Series CEP10SNL / Bathroom Exhaust Fans PD ID 4713814 (Qualified 2026-10-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (100.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match RAB CEP10SNL airflow output?

Annual electricity figures and room square-footage ceilings below reflect RAB CEP10SNL tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for RAB CEP10SNL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 100 sq ft1 CFM/sq ft @ 100.8 CFM
Tall Bath (9-ft Ceiling)Up to 89 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 50 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.8 kWh/yr (~$1.57/yr)26.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2234.8 kWh/yr (~$37.57/yr)26.8 W x 8,760 hrs / 1,000

Which competing models share RAB CEP10SNL airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan AER110RGBL 110 / 97 CFM 1.5 sones 4.1 CFM/W 4 in. diameter
Tech Drive TD-BF-07-plus 110 / 91.6 CFM 1.5 sones 4.1 CFM/W 4 in. diameter
Tech Drive TD-BF-25L-5CCT(BL) 110 / 91.6 CFM 1.5 sones 4.1 CFM/W 4 in. diameter
Commercial Electric 7130-16-CE 110 / 103.8 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Nutone AERN110RGBL 110 / 97.6 CFM 1.5 sones 4.0 CFM/W 4 in. diameter

How much airflow margin does RAB CEP10SNL give your bath?

Run a quick local room-volume check for RAB CEP10SNL by entering square footage and ceiling height to spot under-vented steam risks early.

Who should not install RAB CEP10SNL in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting RAB CEP10SNL for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 100 sq ft with 8-ft ceilings (89 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about RAB CEP10SNL?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to RAB CEP10SNL.

Why check RAB CEP10SNL CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, RAB CEP10SNL registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does RAB CEP10SNL sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, RAB CEP10SNL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define RAB CEP10SNL?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can RAB CEP10SNL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from RAB CEP10SNL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing RAB CEP10SNL?

RAB CEP10SNL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change RAB CEP10SNL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing RAB CEP10SNL's safe coverage footprint from 50 sq ft to 44 sq ft.

Does RAB CEP10SNL satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), RAB CEP10SNL clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is RAB CEP10SNL undersized or poorly matched for a bath renovation?

Skip RAB CEP10SNL if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories