Skip to main content
Grant Estimator

Revent RVSS80100 Exhaust Fan Specifications

ENERGY STAR PD #4520335 · Bathroom/Utility Room · Qualified 2025-12-19
Verified Specification Summary

Certified by EPA ENERGY STAR, Revent RVSS80100 delivers 100 CFM free-air (107.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 107 sq ft (8-ft height) or 95 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVSS80100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 107.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.4 CFM/W (#254/1,145)
Static Retention
107.3% @ 0.25"
Motor Draw
10.6 W (3.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVSS80100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent RVSS80100 (EPA filing PD #4520335) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 107.3 CFM out of 100 CFM (107.3% retention, 19.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Revent's 40-unit lineup, RVSS80100 (series: ReVent) carries PD #4520335 dating to 2025-12-19. Lighting kit: No. At 9.4 CFM/W (#254 of 1,145, top 22.4% of 1,145 rated models, more efficient than 77.6% of rated models, 4.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

Why does rigid 4 in. diameter ducting protect Revent RVSS80100 airflow?

Connecting Revent RVSS80100 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Revent RVSS80100 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Revent RVSS80100 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVSS80100 / ReVent PD ID 4520335 (Qualified 2025-12-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (107.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Revent RVSS80100?

Calculated coverage metrics translate Revent RVSS80100 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Revent RVSS80100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 107 sq ft1 CFM/sq ft @ 107.3 CFM
Tall Bath (9-ft Ceiling)Up to 95 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 57 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.292.9 kWh/yr (~$14.86/yr)10.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Revent RVSS80100?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Revent RVSS80100 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Revent RVSS80100 percentage capacity without sending data.

When does Revent RVSS80100 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Revent RVSS80100.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 57 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 107.3 CFM net static output
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Revent RVSS80100?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Revent RVSS80100.

Is Revent RVSS80100 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Revent RVSS80100 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Revent RVSS80100?

Do not force Revent RVSS80100 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Revent RVSS80100 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Revent RVSS80100 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Revent RVSS80100 disturb adjacent bedrooms during night use?

Acoustic measurement places Revent RVSS80100 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Revent RVSS80100 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Revent RVSS80100 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Revent RVSS80100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVSS80100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVSS80100?

Revent RVSS80100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVSS80100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVSS80100's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories