Skip to main content
Grant Estimator

Tosca 7117-02-BN Exhaust Fan Specifications

ENERGY STAR PD #3629777 · Bathroom/Utility Room · Qualified 2024-09-27
Verified Specification Summary

Homeowners specifying Tosca 7117-02-BN gain 80 CFM at 0.1 in. w.g. (59.5 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 3.6 CFM/W efficacy, venting bathrooms up to 59 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tosca 7117-02-BN Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 59.5 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.6 CFM/W (#1,017/1,145)
Static Retention
74.4% @ 0.25"
Motor Draw
22.2 W (8.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Tosca 7117-02-BN vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.5 CFM at 0.25 in. w.g. (74.4% retention, 13.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Tosca 7117-02-BN (series: 7117-02-BN) under PD #3629777 (1 model registered, 2024-09-27). Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include ACIQ AP80 (80.0 CFM) and Canarm CP80 (80.0 CFM).

What acoustic percentile does Tosca 7117-02-BN occupy among 1,145 bath blowers?

Inspect how Tosca 7117-02-BN positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Which exterior damper path suits Tosca 7117-02-BN best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Tosca 7117-02-BN housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Tosca 7117-02-BN acoustic and static metrics stand?

Compare Tosca 7117-02-BN published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Tosca (1 model) ENERGY STAR Certified Partner
Model Number & Series 7117-02-BN / 7117-02-BN PD ID 3629777 (Qualified 2024-09-27)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (59.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Tosca 7117-02-BN handle taller ceilings or walk-in tub steam?

Evaluate how Tosca 7117-02-BN scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Tosca 7117-02-BN
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 59 sq ft1 CFM/sq ft @ 59.5 CFM
Tall Bath (9-ft Ceiling)Up to 52 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.1 kWh/yr (~$1.30/yr)22.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2194.5 kWh/yr (~$31.12/yr)22.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Tosca 7117-02-BN?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AP80 80 / 71.6 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
Canarm CP80 80 / 71.6 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
Cyclone CT80 80 / 71.6 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
Cyclone CTP80 80 / 71.6 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-02-BN 80 / 59.5 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter

Is Tosca 7117-02-BN sized right for your shower or tub room?

Check whether Tosca 7117-02-BN clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Who should not install Tosca 7117-02-BN in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tosca 7117-02-BN for residential use.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 59.5 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Tosca 7117-02-BN?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tosca 7117-02-BN.

Does Tosca 7117-02-BN satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tosca 7117-02-BN clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Tosca 7117-02-BN undersized or poorly matched for a bath renovation?

Skip Tosca 7117-02-BN if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Tosca 7117-02-BN CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tosca 7117-02-BN registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Tosca 7117-02-BN sound output compare to noisy contractor-grade fans?

Rated at 1.0 sones, Tosca 7117-02-BN operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Tosca 7117-02-BN?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Tosca 7117-02-BN pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tosca 7117-02-BN's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Tosca 7117-02-BN?

Tosca 7117-02-BN features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Tosca 7117-02-BN's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tosca 7117-02-BN's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories