Homeowners specifying Tosca 7117-02-BN gain 80 CFM at 0.1 in. w.g. (59.5 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 3.6 CFM/W efficacy, venting bathrooms up to 59 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tosca 7117-02-BN Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 59.5 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 74.4% @ 0.25"
- Motor Draw
- 22.2 W (8.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Tosca 7117-02-BN vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.5 CFM at 0.25 in. w.g. (74.4% retention, 13.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Tosca 7117-02-BN (series: 7117-02-BN) under PD #3629777 (1 model registered, 2024-09-27). Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include ACIQ AP80 (80.0 CFM) and Canarm CP80 (80.0 CFM).
What acoustic percentile does Tosca 7117-02-BN occupy among 1,145 bath blowers?
Inspect how Tosca 7117-02-BN positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Tosca 7117-02-BN best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Tosca 7117-02-BN housings.
Where do Tosca 7117-02-BN acoustic and static metrics stand?
Compare Tosca 7117-02-BN published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tosca (1 model) | ENERGY STAR Certified Partner |
| Model Number & Series | 7117-02-BN / 7117-02-BN | PD ID 3629777 (Qualified 2024-09-27) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (59.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Tosca 7117-02-BN handle taller ceilings or walk-in tub steam?
Evaluate how Tosca 7117-02-BN scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 59 sq ft | 1 CFM/sq ft @ 59.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.1 kWh/yr (~$1.30/yr) | 22.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 194.5 kWh/yr (~$31.12/yr) | 22.2 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Tosca 7117-02-BN?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Canarm CP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Cyclone CT80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Cyclone CTP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7117-02-BN | 80 / 59.5 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Is Tosca 7117-02-BN sized right for your shower or tub room?
Check whether Tosca 7117-02-BN clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Who should not install Tosca 7117-02-BN in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tosca 7117-02-BN for residential use.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 59.5 CFM net static output
- Primary match: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Tosca 7117-02-BN?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tosca 7117-02-BN.
Does Tosca 7117-02-BN satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tosca 7117-02-BN clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Tosca 7117-02-BN undersized or poorly matched for a bath renovation?
Skip Tosca 7117-02-BN if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Tosca 7117-02-BN CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tosca 7117-02-BN registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Tosca 7117-02-BN sound output compare to noisy contractor-grade fans?
Rated at 1.0 sones, Tosca 7117-02-BN operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Tosca 7117-02-BN?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Tosca 7117-02-BN pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tosca 7117-02-BN's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tosca 7117-02-BN?
Tosca 7117-02-BN features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tosca 7117-02-BN's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tosca 7117-02-BN's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)