Wintek BPT13B-110N4 Exhaust Fan Specifications

ENERGY STAR PD #3629676 · Bathroom/Utility Room · Qualified 2024-06-07
Verified Specification Summary

The Wintek BPT13B-110N4 (BPT13B-110N4) moves 110 CFM at 0.1 in. w.g. (87.4 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 87 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek BPT13B-110N4 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 87.4 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
79.5% @ 0.25"
Motor Draw
26.2 W (9.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Wintek BPT13B-110N4 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 87.4 CFM at 0.25 in. w.g. (79.5% retention, 8.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Wintek BPT13B-110N4 (series: BPT13B-110N4) under PD #3629676 (9 models registered, 2024-06-07). Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Akicon AK13110N4-B (110.0 CFM) and Akicon AK13110N4-S (110.0 CFM).

Where does Wintek BPT13B-110N4 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

How does duct geometry alter Wintek BPT13B-110N4 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Wintek BPT13B-110N4?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Wintek BPT13B-110N4 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Wintek (9 models) ENERGY STAR Certified Partner
Model Number & Series BPT13B-110N4 / BPT13B-110N4 PD ID 3629676 (Qualified 2024-06-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (87.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Wintek BPT13B-110N4 ventilate safely?

Sizing outputs below convert Wintek BPT13B-110N4 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Wintek BPT13B-110N4
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 87 sq ft1 CFM/sq ft @ 87.4 CFM
Tall Bath (9-ft Ceiling)Up to 77 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 37 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2229.5 kWh/yr (~$36.72/yr)26.2 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Wintek BPT13B-110N4 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Akicon AK13110N4-B 110 / 87.4 CFM 2.0 sones (Same) 4.2 CFM/W 4 in. diameter
Akicon AK13110N4-S 110 / 87.4 CFM 2.0 sones (Same) 4.2 CFM/W 4 in. diameter
Akicon AK13110N4-W 110 / 87.4 CFM 2.0 sones (Same) 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPE811 110 / 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPE811K 110 / 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter

Will Wintek BPT13B-110N4 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Wintek BPT13B-110N4 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install Wintek BPT13B-110N4 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Wintek BPT13B-110N4 for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 37 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 87 sq ft with 8-ft ceilings (77 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Wintek BPT13B-110N4?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Wintek BPT13B-110N4.

How does Wintek BPT13B-110N4 sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, Wintek BPT13B-110N4 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Wintek BPT13B-110N4?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Wintek BPT13B-110N4 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek BPT13B-110N4's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Wintek BPT13B-110N4?

Wintek BPT13B-110N4 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Wintek BPT13B-110N4's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek BPT13B-110N4's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Wintek BPT13B-110N4 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Wintek BPT13B-110N4 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Wintek BPT13B-110N4 undersized or poorly matched for a bath renovation?

Skip Wintek BPT13B-110N4 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Wintek BPT13B-110N4 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Wintek BPT13B-110N4 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)