Skip to main content
Grant Estimator

Wintek BPT15A-110 Exhaust Fan Specifications

ENERGY STAR PD #2405573 · Bathroom/Utility Room · Qualified 2022-12-09
Verified Specification Summary

In EPA dataset 8dv7-nngq, Wintek BPT15A-110 tests at 110 CFM free discharge (105.4 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 105 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek BPT15A-110 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 105.4 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
95.8% @ 0.25"
Motor Draw
26.2 W (9.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Wintek BPT15A-110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 105.4 CFM out of 110 CFM (95.8% retention, 8.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Wintek maintains 9 active ENERGY STAR blowers; BPT15A-110 (series: BPT15A-110) (PD #2405573) gained qualification on 2022-12-09. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Akicon AK13110N4-B (110.0 CFM) and Akicon AK13110N4-S (110.0 CFM).

Does Wintek BPT15A-110 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Wintek BPT15A-110 at 2.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why avoid unvented attic termination with Wintek BPT15A-110?

Under ASHRAE 62.2 best practice, Wintek BPT15A-110 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Wintek BPT15A-110?

Before cutting ceiling drywall or sizing attic transitions for Wintek BPT15A-110, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Wintek (9 models) ENERGY STAR Certified Partner
Model Number & Series BPT15A-110 / BPT15A-110 PD ID 2405573 (Qualified 2022-12-09)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (105.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Wintek BPT15A-110?

Bathroom ventilation sizing below maps Wintek BPT15A-110 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Wintek BPT15A-110
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 105 sq ft1 CFM/sq ft @ 105.4 CFM
Tall Bath (9-ft Ceiling)Up to 93 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 55 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2229.5 kWh/yr (~$36.72/yr)26.2 W x 8,760 hrs / 1,000

What peer models sit nearest Wintek BPT15A-110 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Wintek BPT15A-110.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Akicon AK13110N4-B 110 / 87.4 CFM 2.0 sones (Same) 4.2 CFM/W 4 in. diameter
Akicon AK13110N4-S 110 / 87.4 CFM 2.0 sones (Same) 4.2 CFM/W 4 in. diameter
Akicon AK13110N4-W 110 / 87.4 CFM 2.0 sones (Same) 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPE811 110 / 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPE811K 110 / 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter

What percentage of room demand does Wintek BPT15A-110 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Wintek BPT15A-110 tested delivery.

When does Wintek BPT15A-110 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Wintek BPT15A-110.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 105.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 2.0 sones up to 105 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Wintek BPT15A-110?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Wintek BPT15A-110.

How much airflow does Wintek BPT15A-110 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Wintek BPT15A-110 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Wintek BPT15A-110 disturb adjacent bedrooms during night use?

Acoustic measurement places Wintek BPT15A-110 at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Wintek BPT15A-110 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Wintek BPT15A-110 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Wintek BPT15A-110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek BPT15A-110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Wintek BPT15A-110?

Wintek BPT15A-110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Wintek BPT15A-110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek BPT15A-110's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Wintek BPT15A-110 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Wintek BPT15A-110 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Wintek BPT15A-110?

Do not force Wintek BPT15A-110 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories