The Best UCB3I30SBW (UCB3I) moves 160 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 3.2 CFM/W efficacy, sizing bathrooms up to 160 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Best UCB3I30SBW Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 160 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.2 CFM/W (#1,091/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 50.0 W (18.2 kWh/yr)
- Duct & Tier
- 3.25 in. diameter · Standard

What does Best UCB3I30SBW vs. 1,145-Model ENERGY STAR Benchmarks show?
Best UCB3I30SBW (EPA filing PD #2336461) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 3.25 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 3.25 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Best maintains 17 active ENERGY STAR blowers; UCB3I30SBW (series: UCB3I) (PD #2336461) gained qualification on 2019-03-08. Lighting kit: Yes. At 3.2 CFM/W (#1,091 of 1,145, below median tier among 1,145 rated models; more efficient than 4.0% of rated models, 1.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 50.0 watts, about 18.2 kWh/yr (~$2.91/yr at $0.16/kWh) for 1 hr/day shower timers or 438.0 kWh/yr (~$70.08/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and Broan QT150LE (150.0 CFM).
How does duct geometry alter Best UCB3I30SBW static pressure?
Smooth 3.25 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Best UCB3I30SBW?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Best UCB3I30SBW alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Best (17 models) | ENERGY STAR Certified Partner |
| Model Number & Series | UCB3I30SBW / UCB3I | PD ID 2336461 (Qualified 2019-03-08) |
| Duct Connection | 3.25 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (160 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Best UCB3I30SBW ventilate safely?
Sizing outputs below convert Best UCB3I30SBW tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 160 sq ft | 1 CFM/sq ft @ 160 CFM |
| Tall Bath (9-ft Ceiling) | Up to 142 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 110 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 18.2 kWh/yr (~$2.91/yr) | 50.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 438.0 kWh/yr (~$70.08/yr) | 50.0 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Best UCB3I30SBW closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan ALT4306SS | 160 / N/A CFM | Unpublished | 3.1 CFM/W | 3.25 x 10 in. rectangular |
Will Best UCB3I30SBW clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Best UCB3I30SBW satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
What plumbing or duct constraints rule out Best UCB3I30SBW?
Compare where Best UCB3I30SBW excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 110 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 160 sq ft with 8-ft ceilings (142 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 3.25 in. diameter
What key rules and numbers govern Best UCB3I30SBW?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Best UCB3I30SBW.
Is Best UCB3I30SBW quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Best UCB3I30SBW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Best UCB3I30SBW energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Best UCB3I30SBW pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Best UCB3I30SBW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Best UCB3I30SBW?
Best UCB3I30SBW features a 3.25 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Best UCB3I30SBW's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Best UCB3I30SBW's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Best UCB3I30SBW serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Best UCB3I30SBW supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Best UCB3I30SBW for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Best UCB3I30SBW lacks adequate reserve.
How does Best UCB3I30SBW handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Best UCB3I30SBW yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3.25 in. diameter rigid metal ducting protects real exhaust.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)