Skip to main content
Grant Estimator

Broan 744L Exhaust Fan Specifications

ENERGY STAR PD #2740412 · Bathroom/Utility Room · Qualified 2023-11-17
Verified Specification Summary

Rated for 80 CFM open-air (65.4 CFM at 0.25 in. w.g.), Broan 744L omits a published 0.1-inch sone rating and delivers 2.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 65 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan 744L Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 65.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
2.9 CFM/W (#1,132/1,145)
Static Retention
81.8% @ 0.25"
Motor Draw
27.6 W (10.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan 744L vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan 744L (EPA filing PD #2740412) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 65.4 CFM at 0.25 in. w.g. (81.8% retention, 5.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan maintains 207 active ENERGY STAR blowers; 744L (series: RECESSED FAN/LIGHT) (PD #2740412) gained qualification on 2023-11-17. Lighting kit: Yes. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.6 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 241.8 kWh/yr (~$38.69/yr) continuously. Closest competing matches include HomeWerks Worldwide 7140-80-G3 (80.0 CFM) and S&P PCV80 (80.0 CFM).

How do flex elbows choke Broan 744L at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan 744L moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan 744L meet residential exhaust fan code specs?

Inspect Broan 744L mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series 744L / RECESSED FAN/LIGHT PD ID 2740412 (Qualified 2023-11-17)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (65.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Broan 744L airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan 744L tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan 744L
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 65 sq ft1 CFM/sq ft @ 65.4 CFM
Tall Bath (9-ft Ceiling)Up to 58 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.1 kWh/yr (~$1.62/yr)27.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2241.8 kWh/yr (~$38.69/yr)27.6 W x 8,760 hrs / 1,000

Which competing models share Broan 744L airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7140-80-G3 80 / 58.8 CFM 1.5 sones 3.4 CFM/W 4 in. diameter
S&P PCV80 80 / 60.8 CFM 1.5 sones 3.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7140-80 80 / 57.2 CFM 1.5 sones 3.5 CFM/W 4 in. diameter
Wintek BPT13B-80-L4 80 / 57.2 CFM 1.5 sones 3.5 CFM/W 4 in. diameter
PROJECT SOURCE 8781-80-PS 80 / 61.2 CFM 1.5 sones 3.9 CFM/W 4 in. diameter

How much airflow margin does Broan 744L give your bath?

Run a quick local room-volume check for Broan 744L by entering square footage and ceiling height to spot under-vented steam risks early.

Does Broan 744L suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan 744L for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 65 sq ft with 8-ft ceilings (58 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Broan 744L?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan 744L.

What acoustic sone tier does Broan 744L occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan 744L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan 744L add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan 744L averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan 744L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan 744L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan 744L?

Broan 744L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan 744L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan 744L's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan 744L pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan 744L easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan 744L in a bathroom remodel?

Avoid specifying Broan 744L in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan 744L airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan 744L achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories