Skip to main content
Grant Estimator

Panasonic RG-M79LA Exhaust Fan Specifications

ENERGY STAR PD #3543569 · Bathroom/Utility Room · Qualified 2024-05-03
Verified Specification Summary

Tested under HVI protocols, the Panasonic RG-M79LA exhaust unit achieves 90 CFM at 0.1 in. w.g. (77.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 4.1 CFM/W efficacy, covering standard baths up to 77 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-M79LA Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 77.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
86.1% @ 0.25"
Motor Draw
22.0 W (8.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic RG-M79LA vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic RG-M79LA (EPA filing PD #3543569) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 77.5 CFM out of 90 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Panasonic RG-M79LA (series: Whisper Mighty) under PD #3543569 (92 models registered, 2024-05-03). Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.0 watts, about 8.0 kWh/yr (~$1.28/yr at $0.16/kWh) for 1 hr/day shower timers or 192.7 kWh/yr (~$30.83/yr) continuously. Closest competing matches include Akicon AK1390N1-W/B/S (90.0 CFM) and Tech Drive TD-BF-11 (90.0 CFM).

What attic duct routing preserves Panasonic RG-M79LA CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic RG-M79LA, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Panasonic RG-M79LA measure up on airflow and noise ratings?

Each row below breaks down Panasonic RG-M79LA certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series RG-M79LA / Whisper Mighty PD ID 3543569 (Qualified 2024-05-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (77.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Panasonic RG-M79LA CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic RG-M79LA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 77 sq ft1 CFM/sq ft @ 77.5 CFM
Tall Bath (9-ft Ceiling)Up to 68 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 27 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.0 kWh/yr (~$1.28/yr)22.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2192.7 kWh/yr (~$30.83/yr)22.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Panasonic RG-M79LA?

Compare Panasonic RG-M79LA side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Akicon AK1390N1-W/B/S 90 / 67.4 CFM 1.5 sones 4.1 CFM/W 4 in. diameter
Tech Drive TD-BF-11 90 / 82 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Akicon AK1390N2-B 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-S 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-W 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter

Can you size Panasonic RG-M79LA for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic RG-M79LA verified capacity.

Which bath layouts should avoid specifying Panasonic RG-M79LA?

Match Panasonic RG-M79LA directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 77.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 77 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Panasonic RG-M79LA?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic RG-M79LA.

Where does Panasonic RG-M79LA run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic RG-M79LA.

What happens to Panasonic RG-M79LA CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic RG-M79LA moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Panasonic RG-M79LA sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic RG-M79LA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Panasonic RG-M79LA cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic RG-M79LA 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Panasonic RG-M79LA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-M79LA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic RG-M79LA?

Panasonic RG-M79LA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic RG-M79LA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-M79LA's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Panasonic RG-M79LA ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-M79LA covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories