Skip to main content
Grant Estimator

Broan AMG03RSS Exhaust Fan Specifications

ENERGY STAR PD #4510016 · Range Hood · Qualified 2025-09-05
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan AMG03RSS tests at 130 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 130 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AMG03RSS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
0.1" test only
Motor Draw
31.0 W (11.3 kWh/yr)
Duct & Tier
3.25 x 10 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AMG03RSS vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan AMG03RSS (EPA filing PD #4510016) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.

Broan maintains 207 active ENERGY STAR blowers; AMG03RSS (series: RANGE HOOD) (PD #4510016) gained qualification on 2025-09-05. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 31.0 watts, about 11.3 kWh/yr (~$1.81/yr at $0.16/kWh) for 1 hr/day shower timers or 271.6 kWh/yr (~$43.46/yr) continuously. Closest competing matches include Nutone QTN130LE1 (130.0 CFM) and Greenheck SP-B110ES (118.0 CFM).

Why avoid unvented attic termination with Broan AMG03RSS?

Under ASHRAE 62.2 best practice, Broan AMG03RSS needs insulated 3.25 x 10 in. rectangular rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan AMG03RSS?

Before cutting ceiling drywall or sizing attic transitions for Broan AMG03RSS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AMG03RSS / RANGE HOOD PD ID 4510016 (Qualified 2025-09-05)
Duct Connection 3.25 x 10 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (130 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Broan AMG03RSS?

Bathroom ventilation sizing below maps Broan AMG03RSS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan AMG03RSS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 130 sq ft1 CFM/sq ft @ 130 CFM
Tall Bath (9-ft Ceiling)Up to 115 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 80 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.3 kWh/yr (~$1.81/yr)31.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2271.6 kWh/yr (~$43.46/yr)31.0 W x 8,760 hrs / 1,000

What peer models sit nearest Broan AMG03RSS in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan AMG03RSS.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones 4.0 CFM/W 6 in. diameter
KORA SBF110N 119.2 / N/A CFM 1.6 sones 3.5 CFM/W 4 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter

What percentage of room demand does Broan AMG03RSS cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan AMG03RSS tested delivery.

Does Broan AMG03RSS suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan AMG03RSS for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 130 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 130 sq ft
  • Best application: Paired with rigid galvanized 3.25 x 10 in. rectangular transition

Where do official rules set limits for Broan AMG03RSS?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan AMG03RSS.

What acoustic sone tier does Broan AMG03RSS occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan AMG03RSS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan AMG03RSS add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan AMG03RSS averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan AMG03RSS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AMG03RSS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AMG03RSS?

Broan AMG03RSS features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AMG03RSS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AMG03RSS's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan AMG03RSS pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan AMG03RSS easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan AMG03RSS in a bathroom remodel?

Avoid specifying Broan AMG03RSS in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan AMG03RSS airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan AMG03RSS achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3.25 x 10 in. rectangular smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)