In EPA dataset 8dv7-nngq, AUPU V6-13HS tests at 130 CFM free discharge (135.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 135 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU V6-13HS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 135.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.9 CFM/W (#300/1,145)
- Static Retention
- 104.5% @ 0.25"
- Motor Draw
- 14.6 W (5.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU V6-13HS vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU V6-13HS (EPA filing PD #4688894) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 135.8 CFM out of 130 CFM (104.5% retention, 16.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: AUPU registers 35 certified models, with SKU V6-13HS (series: VF6) (PD #4688894) certified since 2026-08-05. Lighting kit: No. At 8.9 CFM/W (#300 of 1,145, top 26.6% of 1,145 rated models, more efficient than 73.4% of rated models, 4.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.6 watts, about 5.3 kWh/yr (~$0.85/yr at $0.16/kWh) for 1 hr/day shower timers or 127.9 kWh/yr (~$20.46/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
Why avoid unvented attic termination with AUPU V6-13HS?
Under ASHRAE 62.2 best practice, AUPU V6-13HS needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern AUPU V6-13HS?
Before cutting ceiling drywall or sizing attic transitions for AUPU V6-13HS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | V6-13HS / VF6 | PD ID 4688894 (Qualified 2026-08-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (135.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit AUPU V6-13HS?
Bathroom ventilation sizing below maps AUPU V6-13HS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 135 sq ft | 1 CFM/sq ft @ 135.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 120 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 85 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.3 kWh/yr (~$0.85/yr) | 14.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 127.9 kWh/yr (~$20.46/yr) | 14.6 W x 8,760 hrs / 1,000 |
What peer models sit nearest AUPU V6-13HS in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AUPU V6-13HS.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
What percentage of room demand does AUPU V6-13HS cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AUPU V6-13HS tested delivery.
Does AUPU V6-13HS suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying AUPU V6-13HS for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 135.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around ENERGY STAR sones up to 135 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for AUPU V6-13HS?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AUPU V6-13HS.
How many kWh per year does AUPU V6-13HS add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, AUPU V6-13HS averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can AUPU V6-13HS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU V6-13HS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU V6-13HS?
AUPU V6-13HS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU V6-13HS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU V6-13HS's safe coverage footprint from 50 sq ft to 44 sq ft.
Does AUPU V6-13HS pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), AUPU V6-13HS easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install AUPU V6-13HS in a bathroom remodel?
Avoid specifying AUPU V6-13HS in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut AUPU V6-13HS airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, AUPU V6-13HS achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does AUPU V6-13HS occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., AUPU V6-13HS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.