In EPA dataset 8dv7-nngq, AUPU V6-13HML tests at 130 CFM free discharge (138.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 138 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU V6-13HML Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 138.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.1 CFM/W (#338/1,145)
- Static Retention
- 106.7% @ 0.25"
- Motor Draw
- 16.0 W (5.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU V6-13HML vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU V6-13HML (EPA filing PD #4688874) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 138.7 CFM out of 130 CFM (106.7% retention, 19.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4688874 verifies V6-13HML (series: VF6) under AUPU (35 listed models, qualified 2026-08-05). Lighting kit: Yes. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.0 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 140.2 kWh/yr (~$22.43/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
Why avoid unvented attic termination with AUPU V6-13HML?
Under ASHRAE 62.2 best practice, AUPU V6-13HML needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern AUPU V6-13HML?
Before cutting ceiling drywall or sizing attic transitions for AUPU V6-13HML, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | V6-13HML / VF6 | PD ID 4688874 (Qualified 2026-08-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (138.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit AUPU V6-13HML?
Bathroom ventilation sizing below maps AUPU V6-13HML motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 138 sq ft | 1 CFM/sq ft @ 138.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 123 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 88 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.8 kWh/yr (~$0.93/yr) | 16.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 140.2 kWh/yr (~$22.43/yr) | 16.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest AUPU V6-13HML in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AUPU V6-13HML.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
What percentage of room demand does AUPU V6-13HML cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AUPU V6-13HML tested delivery.
When does AUPU V6-13HML fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering AUPU V6-13HML.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 138.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 138 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for AUPU V6-13HML?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AUPU V6-13HML.
Is AUPU V6-13HML code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), AUPU V6-13HML clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than AUPU V6-13HML?
Do not force AUPU V6-13HML into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does AUPU V6-13HML retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, AUPU V6-13HML produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will AUPU V6-13HML disturb adjacent bedrooms during night use?
Acoustic measurement places AUPU V6-13HML at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running AUPU V6-13HML continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of AUPU V6-13HML draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can AUPU V6-13HML pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU V6-13HML's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU V6-13HML?
AUPU V6-13HML features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU V6-13HML's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU V6-13HML's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)