Skip to main content
Grant Estimator

Broan AMG63RSS Exhaust Fan Specifications

ENERGY STAR PD #4510011 · Range Hood · Qualified 2025-09-05
Verified Specification Summary

Tested under HVI protocols, the Broan AMG63RSS exhaust unit achieves 150 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #522 of 607 in quietness (2.0 sones) and delivers 4.6 CFM/W efficacy, covering standard baths up to 150 sq ft on a 7 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AMG63RSS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / N/A CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
4.6 CFM/W (#578/1,145)
Static Retention
0.1" test only
Motor Draw
32.6 W (11.9 kWh/yr)
Duct & Tier
7 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AMG63RSS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU AMG63RSS (series: RANGE HOOD) (PD #4510011) certified since 2025-09-05. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Air King EVLD (150.0 CFM) and Air King EVLDGH (150.0 CFM).

Where do Broan AMG63RSS sones rank across EPA ENERGY STAR fans?

Comparing Broan AMG63RSS (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

What attic duct routing preserves Broan AMG63RSS CFM output?

Short straight 7 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AMG63RSS, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan AMG63RSS measure up on airflow and noise ratings?

Each row below breaks down Broan AMG63RSS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AMG63RSS / RANGE HOOD PD ID 4510011 (Qualified 2025-09-05)
Duct Connection 7 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (150 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Broan AMG63RSS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan AMG63RSS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 150 sq ft1 CFM/sq ft @ 150 CFM
Tall Bath (9-ft Ceiling)Up to 133 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 100 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.9 kWh/yr (~$1.90/yr)32.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2285.6 kWh/yr (~$45.70/yr)32.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan AMG63RSS?

Compare Broan AMG63RSS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Air King EVLD 150 / 112.4 CFM Unpublished 4.6 CFM/W 6 in. diameter
Air King EVLDGH 150 / 112.4 CFM Unpublished 4.6 CFM/W 6 in. diameter
Air King EVLDH 150 / 112.4 CFM Unpublished 4.6 CFM/W 6 in. diameter
S&P TD-125XS 150 / N/A CFM Unpublished 4.6 CFM/W 5 in. diameter
Air King E110S 150 / 111.8 CFM Unpublished 4.5 CFM/W 6 in. diameter

Can you size Broan AMG63RSS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AMG63RSS verified capacity.

Who should not install Broan AMG63RSS in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan AMG63RSS for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 150 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 2.0 sones up to 150 sq ft
  • Primary match: Paired with rigid galvanized 7 in. diameter transition

How do federal and code standards apply to Broan AMG63RSS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AMG63RSS.

Does Broan AMG63RSS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan AMG63RSS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan AMG63RSS undersized or poorly matched for a bath renovation?

Skip Broan AMG63RSS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan AMG63RSS CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan AMG63RSS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 7 in. diameter duct runs vital.

How does Broan AMG63RSS sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, Broan AMG63RSS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan AMG63RSS?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan AMG63RSS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AMG63RSS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AMG63RSS?

Broan AMG63RSS features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AMG63RSS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AMG63RSS's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories