Skip to main content
Grant Estimator

Air King EVLDGH Exhaust Fan Specifications

ENERGY STAR PD #2308898 · Bathroom/Utility Room · Qualified 2018-01-05
Verified Specification Summary

Certified by EPA ENERGY STAR, Air King EVLDGH delivers 150 CFM free-air (112.4 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 112 sq ft (8-ft height) or 99 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King EVLDGH Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 112.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.6 CFM/W (#578/1,145)
Static Retention
74.9% @ 0.25"
Motor Draw
32.6 W (11.9 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King EVLDGH vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King EVLDGH (EPA filing PD #2308898) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 112.4 CFM at 0.25 in. w.g. (74.9% retention, 12.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Air King registers 62 certified models, with SKU EVLDGH (series: Air King) (PD #2308898) certified since 2018-01-05. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

Why does rigid 6 in. diameter ducting protect Air King EVLDGH airflow?

Connecting Air King EVLDGH through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Air King EVLDGH performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King EVLDGH lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series EVLDGH / Air King PD ID 2308898 (Qualified 2018-01-05)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Air King EVLDGH?

Calculated coverage metrics translate Air King EVLDGH airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Air King EVLDGH
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.4 CFM
Tall Bath (9-ft Ceiling)Up to 99 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.9 kWh/yr (~$1.90/yr)32.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2285.6 kWh/yr (~$45.70/yr)32.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Air King EVLDGH?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter

Does Air King EVLDGH match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King EVLDGH percentage capacity without sending data.

What plumbing or duct constraints rule out Air King EVLDGH?

Compare where Air King EVLDGH excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 112.4 CFM net static output
  • Suited to: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Air King EVLDGH?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King EVLDGH.

Can Air King EVLDGH serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Air King EVLDGH supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Air King EVLDGH for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Air King EVLDGH lacks adequate reserve.

How does Air King EVLDGH handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Air King EVLDGH yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Air King EVLDGH quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Air King EVLDGH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Air King EVLDGH energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Air King EVLDGH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King EVLDGH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King EVLDGH?

Air King EVLDGH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King EVLDGH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King EVLDGH's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories