Air King EVLD Exhaust Fan Specifications

ENERGY STAR PD #2308900 · Bathroom/Utility Room · Qualified 2018-01-05
Verified Specification Summary

Tested under HVI protocols, the Air King EVLD exhaust unit achieves 150 CFM at 0.1 in. w.g. (112.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy, covering standard baths up to 112 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King EVLD Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 112.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.6 CFM/W (#578/1,145)
Static Retention
74.9% @ 0.25"
Motor Draw
32.6 W (11.9 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King EVLD vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King EVLD (EPA filing PD #2308900) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 112.4 CFM at 0.25 in. w.g. (74.9% retention, 12.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Air King maintains 62 active ENERGY STAR blowers; EVLD (series: Air King) (PD #2308900) gained qualification on 2018-01-05. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

What attic duct routing preserves Air King EVLD CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Air King EVLD, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Air King EVLD measure up on airflow and noise ratings?

Each row below breaks down Air King EVLD certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series EVLD / Air King PD ID 2308900 (Qualified 2018-01-05)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Air King EVLD CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Air King EVLD
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.4 CFM
Tall Bath (9-ft Ceiling)Up to 99 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.9 kWh/yr (~$1.90/yr)32.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2285.6 kWh/yr (~$45.70/yr)32.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Air King EVLD?

Compare Air King EVLD side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter

Can you size Air King EVLD for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Air King EVLD verified capacity.

What plumbing or duct constraints rule out Air King EVLD?

Compare where Air King EVLD excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 112.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around ENERGY STAR sones up to 112 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Air King EVLD?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Air King EVLD.

Is Air King EVLD quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Air King EVLD produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Air King EVLD energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Air King EVLD pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King EVLD's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King EVLD?

Air King EVLD features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King EVLD's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King EVLD's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Air King EVLD serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Air King EVLD supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Air King EVLD for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Air King EVLD lacks adequate reserve.

How does Air King EVLD handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Air King EVLD yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.