Rated for 150 CFM open-air (113.5 CFM at 0.25 in. w.g.), Air King EVDH omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 113 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King EVDH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 113.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 75.7% @ 0.25"
- Motor Draw
- 33.3 W (12.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Air King EVDH vs. 1,145-Model ENERGY STAR Benchmarks show?
Air King EVDH (EPA filing PD #2382326) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 113.5 CFM at 0.25 in. w.g. (75.7% retention, 12.0 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #2382326 verifies EVDH (series: Air King) under Air King (62 listed models, qualified 2021-07-16). Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).
How do flex elbows choke Air King EVDH at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Air King EVDH moving full rated CFM.
Does Air King EVDH meet residential exhaust fan code specs?
Inspect Air King EVDH mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EVDH / Air King | PD ID 2382326 (Qualified 2021-07-16) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (113.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Air King EVDH airflow output?
Annual electricity figures and room square-footage ceilings below reflect Air King EVDH tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 113 sq ft | 1 CFM/sq ft @ 113.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 63 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |
Which competing models share Air King EVDH airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
How much airflow margin does Air King EVDH give your bath?
Run a quick local room-volume check for Air King EVDH by entering square footage and ceiling height to spot under-vented steam risks early.
When does Air King EVDH fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Air King EVDH.
Limitations & Who Should Skip
- Steam or walk-in tub room > 63 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 113 sq ft with 8-ft ceilings (100 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Air King EVDH?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Air King EVDH.
Is Air King EVDH code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Air King EVDH clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Air King EVDH?
Do not force Air King EVDH into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Air King EVDH retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Air King EVDH produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Will Air King EVDH disturb adjacent bedrooms during night use?
Acoustic measurement places Air King EVDH at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Air King EVDH continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Air King EVDH draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Air King EVDH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King EVDH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King EVDH?
Air King EVDH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King EVDH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King EVDH's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)