Tested under HVI protocols, the Air King EVLDH exhaust unit achieves 150 CFM at 0.1 in. w.g. (112.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy, covering standard baths up to 112 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King EVLDH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 112.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 74.9% @ 0.25"
- Motor Draw
- 32.6 W (11.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Air King EVLDH vs. 1,145-Model ENERGY STAR Benchmarks show?
Air King EVLDH (EPA filing PD #2308899) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 112.4 CFM at 0.25 in. w.g. (74.9% retention, 12.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Air King maintains 62 active ENERGY STAR blowers; EVLDH (series: Air King) (PD #2308899) gained qualification on 2018-01-05. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).
What attic duct routing preserves Air King EVLDH CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Air King EVLDH, preventing premature peeling paint and mold growth.
How does Air King EVLDH measure up on airflow and noise ratings?
Each row below breaks down Air King EVLDH certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EVLDH / Air King | PD ID 2308899 (Qualified 2018-01-05) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (112.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Air King EVLDH CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Air King EVLDH?
Compare Air King EVLDH side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
Can you size Air King EVLDH for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Air King EVLDH verified capacity.
Which bath layouts should avoid specifying Air King EVLDH?
Match Air King EVLDH directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 112.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around ENERGY STAR sones up to 112 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Air King EVLDH?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Air King EVLDH.
What happens to Air King EVLDH CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Air King EVLDH moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Air King EVLDH sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Air King EVLDH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Air King EVLDH cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Air King EVLDH 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Air King EVLDH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King EVLDH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King EVLDH?
Air King EVLDH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King EVLDH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King EVLDH's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Air King EVLDH ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King EVLDH covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Air King EVLDH run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King EVLDH.