In EPA dataset 8dv7-nngq, Broan BBN2303SS tests at 100 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 3.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 100 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan BBN2303SS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 33.3 W (12.2 kWh/yr)
- Duct & Tier
- 3.25 x 10 in. rectangular · Standard

What does Broan BBN2303SS vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan BBN2303SS (EPA filing PD #2384227) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.
Certification audit confirms Broan BBN2303SS (series: RANGE HOOD) under PD #2384227 (207 models registered, 2021-08-27). Lighting kit: Yes. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Hunter 90064A (100.0 CFM) and Hunter 90065A (100.0 CFM).
Why avoid unvented attic termination with Broan BBN2303SS?
Under ASHRAE 62.2 best practice, Broan BBN2303SS needs insulated 3.25 x 10 in. rectangular rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan BBN2303SS?
Before cutting ceiling drywall or sizing attic transitions for Broan BBN2303SS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BBN2303SS / RANGE HOOD | PD ID 2384227 (Qualified 2021-08-27) |
| Duct Connection | 3.25 x 10 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan BBN2303SS?
Bathroom ventilation sizing below maps Broan BBN2303SS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan BBN2303SS in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan BBN2303SS.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hunter 90064A | 100 / 89.6 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |
| Hunter 90065A | 100 / 89.6 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106MB | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106WH | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Fantech SMPL100 (484302) | 100 / 91.2 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
What percentage of room demand does Broan BBN2303SS cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan BBN2303SS tested delivery.
When does Broan BBN2303SS fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan BBN2303SS.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 100 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 100 sq ft
- Target scenario: Paired with rigid galvanized 3.25 x 10 in. rectangular transition
Where do official rules set limits for Broan BBN2303SS?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan BBN2303SS.
Is Broan BBN2303SS code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan BBN2303SS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan BBN2303SS?
Do not force Broan BBN2303SS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan BBN2303SS retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan BBN2303SS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3.25 x 10 in. rectangular metal duct transitions.
Will Broan BBN2303SS disturb adjacent bedrooms during night use?
Acoustic measurement places Broan BBN2303SS at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan BBN2303SS continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan BBN2303SS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan BBN2303SS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan BBN2303SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan BBN2303SS?
Broan BBN2303SS features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan BBN2303SS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan BBN2303SS's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)