In EPA dataset 8dv7-nngq, Broan-Nutone LP510R tests at 100 CFM free discharge (97 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 97 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone LP510R Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 97 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.1 CFM/W (#292/1,145)
- Static Retention
- 97.0% @ 0.25"
- Motor Draw
- 11.0 W (4.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone LP510R vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone LP510R (EPA filing PD #2405576) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97 CFM out of 100 CFM (97.0% retention, 9.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan-Nutone LP510R (series: LP) under PD #2405576 (48 models registered, 2022-11-04). Lighting kit: No. At 9.1 CFM/W (#292 of 1,145, top 25.9% of 1,145 rated models, more efficient than 74.1% of rated models, 4.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.0 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 96.4 kWh/yr (~$15.42/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).
Why avoid unvented attic termination with Broan-Nutone LP510R?
Under ASHRAE 62.2 best practice, Broan-Nutone LP510R needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan-Nutone LP510R?
Before cutting ceiling drywall or sizing attic transitions for Broan-Nutone LP510R, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | LP510R / LP | PD ID 2405576 (Qualified 2022-11-04) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (97 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan-Nutone LP510R?
Bathroom ventilation sizing below maps Broan-Nutone LP510R motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 97 sq ft | 1 CFM/sq ft @ 97 CFM |
| Tall Bath (9-ft Ceiling) | Up to 86 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 47 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 11.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 96.4 kWh/yr (~$15.42/yr) | 11.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan-Nutone LP510R in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan-Nutone LP510R.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
What percentage of room demand does Broan-Nutone LP510R cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan-Nutone LP510R tested delivery.
Where should contractors skip Broan-Nutone LP510R on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone LP510R carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 97 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 97 sq ft
- Works well for: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Broan-Nutone LP510R?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan-Nutone LP510R.
What duct and room conditions disqualify Broan-Nutone LP510R?
Rule out Broan-Nutone LP510R when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Broan-Nutone LP510R capacity?
Because static drag at 0.25 in. w.g. lowers Broan-Nutone LP510R from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan-Nutone LP510R compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Broan-Nutone LP510R produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Broan-Nutone LP510R consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan-Nutone LP510R draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan-Nutone LP510R pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone LP510R's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone LP510R?
Broan-Nutone LP510R features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone LP510R's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone LP510R's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan-Nutone LP510R score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone LP510R delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)