Skip to main content
Grant Estimator

Broan BCSEK130BL Exhaust Fan Specifications

ENERGY STAR PD #2371791 · Range Hood · Qualified 2021-01-08
Verified Specification Summary

Rated for 150 CFM open-air (unpublished 0.25 in. w.g. output), Broan BCSEK130BL omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 150 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan BCSEK130BL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.5 CFM/W (#471/1,145)
Static Retention
0.1" test only
Motor Draw
27.3 W (10.0 kWh/yr)
Duct & Tier
7 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan BCSEK130BL vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan BCSEK130BL (EPA filing PD #2371791) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places BCSEK130BL (series: RANGE HOOD) (PD #2371791) among 207 Broan entries qualified through 2021-01-08. Lighting kit: Yes. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.3 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 239.1 kWh/yr (~$38.26/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).

How do flex elbows choke Broan BCSEK130BL at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 7 in. diameter metal pipe keeps Broan BCSEK130BL moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan BCSEK130BL meet residential exhaust fan code specs?

Inspect Broan BCSEK130BL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series BCSEK130BL / RANGE HOOD PD ID 2371791 (Qualified 2021-01-08)
Duct Connection 7 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (150 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Broan BCSEK130BL airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan BCSEK130BL tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan BCSEK130BL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 150 sq ft1 CFM/sq ft @ 150 CFM
Tall Bath (9-ft Ceiling)Up to 133 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 100 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.0 kWh/yr (~$1.60/yr)27.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2239.1 kWh/yr (~$38.26/yr)27.3 W x 8,760 hrs / 1,000

Which competing models share Broan BCSEK130BL airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter

How much airflow margin does Broan BCSEK130BL give your bath?

Run a quick local room-volume check for Broan BCSEK130BL by entering square footage and ceiling height to spot under-vented steam risks early.

Does Broan BCSEK130BL suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan BCSEK130BL for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 100 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 150 sq ft with 8-ft ceilings (133 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 7 in. diameter

What should homeowners verify first about Broan BCSEK130BL?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan BCSEK130BL.

Does duct resistance cut Broan BCSEK130BL airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan BCSEK130BL achieves unlisted 0.25 in. w.g. backpressure figures; matching a 7 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan BCSEK130BL occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan BCSEK130BL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan BCSEK130BL add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan BCSEK130BL averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan BCSEK130BL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan BCSEK130BL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan BCSEK130BL?

Broan BCSEK130BL features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan BCSEK130BL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan BCSEK130BL's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan BCSEK130BL pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan BCSEK130BL easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan BCSEK130BL in a bathroom remodel?

Avoid specifying Broan BCSEK130BL in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)