Certified by EPA ENERGY STAR, Broan BCSEK130WW delivers 150 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 150 sq ft (8-ft height) or 133 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan BCSEK130WW Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.5 CFM/W (#471/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 27.3 W (10.0 kWh/yr)
- Duct & Tier
- 7 in. diameter · Standard

What does Broan BCSEK130WW vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan BCSEK130WW (EPA filing PD #2371794) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan BCSEK130WW (series: RANGE HOOD) under PD #2371794 (207 models registered, 2021-01-08). Lighting kit: Yes. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.3 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 239.1 kWh/yr (~$38.26/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).
Why does rigid 7 in. diameter ducting protect Broan BCSEK130WW airflow?
Connecting Broan BCSEK130WW through rigid 7 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan BCSEK130WW performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan BCSEK130WW lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BCSEK130WW / RANGE HOOD | PD ID 2371794 (Qualified 2021-01-08) |
| Duct Connection | 7 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan BCSEK130WW?
Calculated coverage metrics translate Broan BCSEK130WW airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.0 kWh/yr (~$1.60/yr) | 27.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 239.1 kWh/yr (~$38.26/yr) | 27.3 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan BCSEK130WW?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
Does Broan BCSEK130WW match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan BCSEK130WW percentage capacity without sending data.
When does Broan BCSEK130WW fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan BCSEK130WW.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 100 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 150 CFM net static output
- Target scenario: Collar pairs with 7 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan BCSEK130WW?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan BCSEK130WW.
Is Broan BCSEK130WW code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan BCSEK130WW clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan BCSEK130WW?
Do not force Broan BCSEK130WW into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan BCSEK130WW retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan BCSEK130WW produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 7 in. diameter metal duct transitions.
Will Broan BCSEK130WW disturb adjacent bedrooms during night use?
Acoustic measurement places Broan BCSEK130WW at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan BCSEK130WW continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan BCSEK130WW draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan BCSEK130WW pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan BCSEK130WW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan BCSEK130WW?
Broan BCSEK130WW features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan BCSEK130WW's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan BCSEK130WW's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)