Broan BCSEK136BL Exhaust Fan Specifications

ENERGY STAR PD #2448304 · Range Hood · Qualified 2023-03-24
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan BCSEK136BL tests at 150 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 150 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan BCSEK136BL Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.5 CFM/W (#471/1,145)
Static Retention
0.1" test only
Motor Draw
27.3 W (10.0 kWh/yr)
Duct & Tier
7 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan BCSEK136BL vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan BCSEK136BL (EPA filing PD #2448304) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan BCSEK136BL (series: RANGE HOOD) under PD #2448304 (207 models registered, 2023-03-24). Lighting kit: Yes. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.3 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 239.1 kWh/yr (~$38.26/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).

Why avoid unvented attic termination with Broan BCSEK136BL?

Under ASHRAE 62.2 best practice, Broan BCSEK136BL needs insulated 7 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan BCSEK136BL?

Before cutting ceiling drywall or sizing attic transitions for Broan BCSEK136BL, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series BCSEK136BL / RANGE HOOD PD ID 2448304 (Qualified 2023-03-24)
Duct Connection 7 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (150 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Broan BCSEK136BL?

Bathroom ventilation sizing below maps Broan BCSEK136BL motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan BCSEK136BL
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 150 sq ft1 CFM/sq ft @ 150 CFM
Tall Bath (9-ft Ceiling)Up to 133 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 100 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.0 kWh/yr (~$1.60/yr)27.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2239.1 kWh/yr (~$38.26/yr)27.3 W x 8,760 hrs / 1,000

What peer models sit nearest Broan BCSEK136BL in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan BCSEK136BL.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter

What percentage of room demand does Broan BCSEK136BL cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan BCSEK136BL tested delivery.

Which bath layouts should avoid specifying Broan BCSEK136BL?

Match Broan BCSEK136BL directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 150 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 150 sq ft
  • Optimal use: Paired with rigid galvanized 7 in. diameter transition

Where do official rules set limits for Broan BCSEK136BL?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan BCSEK136BL.

What does Broan BCSEK136BL cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan BCSEK136BL 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Broan BCSEK136BL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan BCSEK136BL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan BCSEK136BL?

Broan BCSEK136BL features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan BCSEK136BL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan BCSEK136BL's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Broan BCSEK136BL ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan BCSEK136BL covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Broan BCSEK136BL run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan BCSEK136BL.

What happens to Broan BCSEK136BL CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan BCSEK136BL moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 7 in. diameter collar.

Where does Broan BCSEK136BL sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Broan BCSEK136BL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.