Certified by EPA ENERGY STAR, Delta ELT50-110LED delivers 110 CFM free-air (113.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 113 sq ft (8-ft height) or 101 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT50-110LED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 113.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.6 CFM/W (#206/1,145)
- Static Retention
- 103.4% @ 0.25"
- Motor Draw
- 11.5 W (4.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta ELT50-110LED vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta ELT50-110LED (EPA filing PD #4619015) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.7 CFM out of 110 CFM (103.4% retention, 15.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Delta's 121-unit lineup, ELT50-110LED (series: BreezElite) carries PD #4619015 dating to 2026-03-25. Lighting kit: Yes. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
Why does rigid 4 in. diameter ducting protect Delta ELT50-110LED airflow?
Connecting Delta ELT50-110LED through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Delta ELT50-110LED performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta ELT50-110LED lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ELT50-110LED / BreezElite | PD ID 4619015 (Qualified 2026-03-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (113.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Delta ELT50-110LED?
Calculated coverage metrics translate Delta ELT50-110LED airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 113 sq ft | 1 CFM/sq ft @ 113.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 63 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 100.7 kWh/yr (~$16.11/yr) | 11.5 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Delta ELT50-110LED?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Does Delta ELT50-110LED match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta ELT50-110LED percentage capacity without sending data.
When does Delta ELT50-110LED fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta ELT50-110LED.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 63 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 113.7 CFM net static output
- Target scenario: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Delta ELT50-110LED?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta ELT50-110LED.
Does running Delta ELT50-110LED continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Delta ELT50-110LED draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Delta ELT50-110LED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT50-110LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta ELT50-110LED?
Delta ELT50-110LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta ELT50-110LED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT50-110LED's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Delta ELT50-110LED code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta ELT50-110LED clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Delta ELT50-110LED?
Do not force Delta ELT50-110LED into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Delta ELT50-110LED retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Delta ELT50-110LED produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Delta ELT50-110LED disturb adjacent bedrooms during night use?
Acoustic measurement places Delta ELT50-110LED at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)